Unknown

Dataset Information

0

Transparent and flexible passivation of MoS2/Ag nanowire with sputtered polytetrafluoroethylene film for high performance flexible heaters.


ABSTRACT: We demonstrated highly transparent and flexible polytetrafluoroethylene (PTFE) passivation for the MoS2/Ag nanowire (Ag NW) electrodes used in thin film heaters (TFHs). The electrical, optical, and mechanical properties of PTFE coated MoS2/Ag NW electrode were compared to the bare MoS2/Ag NW electrode to demonstrate effective passivation of the sputtered PTFE films before and after the 85 °C-85% temperature-relative humidity environment test. In addition, we investigated the performances of TFHs with PTFE/MoS2/Ag NW as a function of PTFE thickness from 50 to 200 nm. The saturation temperature (87.3 °C) of TFHs with PTFE/MoS2/Ag NW electrode is higher than that (61.3 °C) of TFHs with bare MoS2/Ag NW, even after the 85 °C-85% temperature-relative humidity environment test, due to effective passivation of the PTFE layer. This indicates that transparent PTFE film prepared by sputtering process provides effective thin film passivation for the two-dimensional (2D) MoS2 and Ag NW hybrid electrode against harsh environment condition.

SUBMITTER: Choi SG 

PROVIDER: S-EPMC8994750 | biostudies-literature | 2022 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Transparent and flexible passivation of MoS<sub>2</sub>/Ag nanowire with sputtered polytetrafluoroethylene film for high performance flexible heaters.

Choi Seung-Gyun SG   Seok Hae-Jun HJ   Kim Jihyun J   Kang Joohoon J   Kim Han-Ki HK  

Scientific reports 20220409 1


We demonstrated highly transparent and flexible polytetrafluoroethylene (PTFE) passivation for the MoS<sub>2</sub>/Ag nanowire (Ag NW) electrodes used in thin film heaters (TFHs). The electrical, optical, and mechanical properties of PTFE coated MoS<sub>2</sub>/Ag NW electrode were compared to the bare MoS<sub>2</sub>/Ag NW electrode to demonstrate effective passivation of the sputtered PTFE films before and after the 85 °C-85% temperature-relative humidity environment test. In addition, we inve  ...[more]

Similar Datasets

| S-EPMC7919462 | biostudies-literature
| S-EPMC9080517 | biostudies-literature
| S-EPMC9056558 | biostudies-literature
| S-EPMC9000623 | biostudies-literature
| S-EPMC9060799 | biostudies-literature
| S-EPMC6471350 | biostudies-literature
| S-EPMC5269670 | biostudies-literature
| S-EPMC7239933 | biostudies-literature
| S-EPMC5599587 | biostudies-literature
| S-EPMC5039627 | biostudies-literature