A Multianalyte Electrochemical Genosensor for the Detection of High-Risk HPV Genotypes in Oral and Cervical Cancers.


ABSTRACT: Infection with high-risk human papillomavirus (HPV) is a major risk factor for oral and cervical cancers. Hence, we developed a multianalyte electrochemical DNA biosensor that could be used for both oral and cervical samples to detect the high-risk HPV genotypes 16 and 18. The assay involves the sandwich hybridization of the HPV target to the silica-redox dye reporter probe and capture probe, followed by electrochemical detection. The sensor was found to be highly specific and sensitive, with a detection limit of 22 fM for HPV-16 and 20 fM for HPV-18, between the range of 1 fM and 1 µM. Evaluation with oral and cervical samples showed that the biosensor result was consistent with the nested PCR/gel electrophoresis detection. The biosensor assay could be completed within 90 min. Due to its simplicity, rapidity, and high sensitivity, this biosensor could be used as an alternative method for HPV detection in clinical laboratories as well as for epidemiological studies.

SUBMITTER: Chaibun T 

PROVIDER: S-EPMC9138520 | biostudies-literature | 2022 May

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Multianalyte Electrochemical Genosensor for the Detection of High-Risk HPV Genotypes in Oral and Cervical Cancers.

Chaibun Thanyarat T   Thanasapburachot Patcharanin P   Chatchawal Patutong P   Su Yin Lee L   Jiaranuchart Sirimanas S   Jearanaikoon Patcharee P   Promptmas Chamras C   Buajeeb Waranun W   Lertanantawong Benchaporn B  

Biosensors 20220502 5


Infection with high-risk human papillomavirus (HPV) is a major risk factor for oral and cervical cancers. Hence, we developed a multianalyte electrochemical DNA biosensor that could be used for both oral and cervical samples to detect the high-risk HPV genotypes 16 and 18. The assay involves the sandwich hybridization of the HPV target to the silica-redox dye reporter probe and capture probe, followed by electrochemical detection. The sensor was found to be highly specific and sensitive, with a  ...[more]

Similar Datasets

| S-EPMC9012668 | biostudies-literature
| S-EPMC9994388 | biostudies-literature
| S-EPMC7160926 | biostudies-literature
| S-EPMC7827051 | biostudies-literature
2021-07-28 | GSE144293 | GEO
| S-EPMC8164037 | biostudies-literature
| S-EPMC5355105 | biostudies-literature
| S-EPMC8063423 | biostudies-literature
| S-EPMC7326398 | biostudies-literature
| S-EPMC9410291 | biostudies-literature