Optical scatter imaging of resected breast tumor structures matches the patterns of micro-computed tomography.


ABSTRACT: In patients undergoing breast-conserving surgery (BCS), the rate of re-excision procedures to remove residual tumor left behind after initial resection can be high. Projection radiography, and recently, volumetric x-ray imaging are used to assess margin adequacy, but x-ray imaging lacks contrast between healthy, abnormal benign, and malignant fibrous tissues important for surgical decision making. The purpose of this study was to compare micro-CT and optical scatter imagery of surgical breast specimens and to demonstrate enhanced contrast-to intra-tumoral morphologies and tumor boundary features revealed by optical scatter imaging. A total of 57 breast tumor slices from 57 patients were imagedex vivoby spatially co-registered micro-CT and optical scatter scanning. Optical scatter exhibited greater similarity with micro-CT in 89% (51/57) of specimens versus diffuse white light (DWL) luminance using mutual information (mean ± standard deviation of 0.48 ± 0.21 versus 0.24 ± 0.12;p < 0.001) and in 81% (46/57) of specimens using the Sørensen-Dice coefficient (0.48 ± 0.21 versus 0.33 ± 0.18;p < 0.001). The coefficient of variation (CV) quantified the feature content in each image. Optical scatter exhibited the highest CV in every specimen (optical scatter: 0.70 ± 0.17; diffuse luminance: 0.24 ± 01; micro-CT: 0.15 ± 0.03 for micro-CT;p < 0.001). Optical scatter also exhibited the highest contrast ratios across representative tumor boundaries with adjacent healthy/benign fibrous tissues (1.5-3.7 for optical scatter; 1.0-1.1 for diffuse luminance; 1.0-1.1 for micro-CT). The two main findings from this study were: first, optical scatter contrast was in general similar to the radiological view of the tissue relative to DWL imaging; and second, optical scatter revealed additional features associated with fibrous tissue structures of similar radiodensity that may be relevant to diagnosis. The value of micro-CT lies in its rapid three-dimensional scanning of specimen morphology, and combined with optical scatter imaging with sensitivity to fibrous surface tissues, may be an attractive solution for margin assessment during BCS.

SUBMITTER: Streeter SS 

PROVIDER: S-EPMC9161376 | biostudies-literature | 2021 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Optical scatter imaging of resected breast tumor structures matches the patterns of micro-computed tomography.

Streeter Samuel S SS   Maloney Benjamin W BW   Zuurbier Rebecca A RA   Wells Wendy A WA   Barth Richard J RJ   Paulsen Keith D KD   Pogue Brian W BW  

Physics in medicine and biology 20210601 11


In patients undergoing breast-conserving surgery (BCS), the rate of re-excision procedures to remove residual tumor left behind after initial resection can be high. Projection radiography, and recently, volumetric x-ray imaging are used to assess margin adequacy, but x-ray imaging lacks contrast between healthy, abnormal benign, and malignant fibrous tissues important for surgical decision making. The purpose of this study was to compare micro-CT and optical scatter imagery of surgical breast sp  ...[more]

Similar Datasets

| S-EPMC5589810 | biostudies-literature
| S-EPMC3408091 | biostudies-literature
| S-EPMC6407623 | biostudies-literature
| S-EPMC6823983 | biostudies-literature
| S-EPMC7401960 | biostudies-literature
| S-EPMC6886258 | biostudies-literature
| S-EPMC3779602 | biostudies-literature
| S-EPMC4724942 | biostudies-literature
| S-EPMC7339758 | biostudies-literature
| S-EPMC2841094 | biostudies-literature