Accuracy of sleep bruxism scoring based on electromyography traces of different jaw muscles in individuals with obstructive sleep apnea.


ABSTRACT:

Study objectives

Sleep bruxism is characterized by rhythmic masticatory muscle activity (RMMA). This study aimed to determine the number and type of jaw muscles needed for a valid RMMA scoring in individuals with obstructive sleep apnea.

Methods

Ten individuals with obstructive sleep apnea (4 males; age, 50.1 ± 8.1 years) were included in this study. RMMA was scored using 1 or more of the following jaw muscles' electromyography (EMG) traces of polysomnography recordings: bilateral masseter and temporalis (4MT; the reference standard), unilateral masseter (1M), bilateral masseter (2M), unilateral temporalis (1T), bilateral temporalis (2T), unilateral chin EMG (1C), and bilateral chin EMG (2C).

Results

1M, 2M, 1T, and 2T showed excellent agreement with 4MT (intraclass correlation coefficient = 0.751, 0.976, 0.815, and 0.950, respectively), while 1C and 2C presented fair agreement (intraclass correlation coefficient = 0.662 and 0.657). In addition, 2M and 2T displayed good sensitivity (87.8% and 72.0%) and positive predictive value (83.1% and 76.0%). In contrast, 1M and 1T had good sensitivity (88.4% and 87.8%) but fair positive predictive value (60.1% and 53.2%). 1C and 2C showed poor sensitivity (41.1% and 40.3%) and fair positive predictive value (62.9% and 60.6%).

Conclusions

Polysomnography with bilateral masseter or temporalis muscle EMG traces is regarded valid in RMMA scoring in individuals with obstructive sleep apnea. In contrast, unilateral masseter or temporalis muscle EMG showed only fair accuracy, and chin EMG had poor accuracy. Consequently, these montages cannot be recommended for RMMA scoring in the presence of obstructive sleep apnea.

Clinical trial registration

Registry: ClinicalTrials.gov; Name: The Effects of Oral Appliance Therapy on Masseter Muscle Activity in Obstructive Sleep Apnea; URL: https://clinicaltrials.gov/ct2/show/NCT02011425; Identifier: NCT02011425.

Citation

Li D, Aarab G, Lobbezoo F, Arcache P, Lavigne GJ, Huynh N. Accuracy of sleep bruxism scoring based on electromyography traces of different jaw muscles in individuals with obstructive sleep apnea. J Clin Sleep Med. 2022;18(6):1609-1615.

SUBMITTER: Li D 

PROVIDER: S-EPMC9163627 | biostudies-literature | 2022 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Accuracy of sleep bruxism scoring based on electromyography traces of different jaw muscles in individuals with obstructive sleep apnea.

Li Deshui D   Aarab Ghizlane G   Lobbezoo Frank F   Arcache Patrick P   Lavigne Gilles J GJ   Huynh Nelly N  

Journal of clinical sleep medicine : JCSM : official publication of the American Academy of Sleep Medicine 20220601 6


<h4>Study objectives</h4>Sleep bruxism is characterized by rhythmic masticatory muscle activity (RMMA). This study aimed to determine the number and type of jaw muscles needed for a valid RMMA scoring in individuals with obstructive sleep apnea.<h4>Methods</h4>Ten individuals with obstructive sleep apnea (4 males; age, 50.1 ± 8.1 years) were included in this study. RMMA was scored using 1 or more of the following jaw muscles' electromyography (EMG) traces of polysomnography recordings: bilateral  ...[more]

Similar Datasets

| S-EPMC9323077 | biostudies-literature
| S-EPMC6832407 | biostudies-literature
| S-EPMC9313411 | biostudies-literature
2012-09-01 | E-GEOD-38792 | biostudies-arrayexpress
2012-09-01 | GSE38792 | GEO
| S-EPMC7079051 | biostudies-literature
| S-EPMC9081718 | biostudies-literature
| S-EPMC8027470 | biostudies-literature
| S-EPMC6175792 | biostudies-literature
| S-EPMC8314631 | biostudies-literature