Computational Fractional Flow Reserve From Coronary Computed Tomography Angiography-Optical Coherence Tomography Fusion Images in Assessing Functionally Significant Coronary Stenosis.


ABSTRACT:

Background

Coronary computed tomography angiography (CTA) and optical coherence tomography (OCT) provide additional functional information beyond the anatomy by applying computational fluid dynamics (CFD). This study sought to evaluate a novel approach for estimating computational fractional flow reserve (FFR) from coronary CTA-OCT fusion images.

Methods

Among patients who underwent coronary CTA, 148 patients who underwent both pressure wire-based FFR measurement and OCT during angiography to evaluate intermediate stenosis in the left anterior descending artery were included from the prospective registry. Coronary CTA-OCT fusion images were created, and CFD was applied to estimate computational FFR. Based on pressure wire-based FFR as a reference, the diagnostic performance of Fusion-FFR was compared with that of CT-FFR and OCT-FFR.

Results

Fusion-FFR was strongly correlated with FFR (r = 0.836, P < 0.001). Correlation between FFR and Fusion-FFR was stronger than that between FFR and CT-FFR (r = 0.682, P < 0.001; z statistic, 5.42, P < 0.001) and between FFR and OCT-FFR (r = 0.705, P < 0.001; z statistic, 4.38, P < 0.001). Area under the receiver operating characteristics curve to assess functionally significant stenosis was higher for Fusion-FFR than for CT-FFR (0.90 vs. 0.83, P = 0.024) and OCT-FFR (0.90 vs. 0.83, P = 0.043). Fusion-FFR exhibited 84.5% accuracy, 84.6% sensitivity, 84.3% specificity, 80.9% positive predictive value, and 87.5% negative predictive value. Especially accuracy, specificity, and positive predictive value were superior for Fusion-FFR than for CT-FFR (73.0%, P = 0.007; 61.4%, P < 0.001; 64.0%, P < 0.001) and OCT-FFR (75.7%, P = 0.021; 73.5%, P = 0.020; 69.9%, P = 0.012).

Conclusion

CFD-based computational FFR from coronary CTA-OCT fusion images provided more accurate functional information than coronary CTA or OCT alone.

Clinical trial registration

[www.ClinicalTrials.gov], identifier [NCT03298282].

SUBMITTER: Lee YJ 

PROVIDER: S-EPMC9234158 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC4751165 | biostudies-literature
| S-EPMC6553476 | biostudies-literature
| S-EPMC4830909 | biostudies-literature
| S-EPMC7074264 | biostudies-literature
| S-EPMC7081838 | biostudies-literature
| S-EPMC6070545 | biostudies-literature
| S-EPMC9905417 | biostudies-literature
| S-EPMC8452917 | biostudies-literature
| S-EPMC10854174 | biostudies-literature