URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome.


ABSTRACT:

Background

The HEART score is a validated risk stratification tool for chest pain patients presenting to the emergency department and was recently investigated for implementation in a pre-hospital setting. Fingerstick (capillary blood) point-of-care (POC) troponin testing enables quick measurements outside the hospital and seems easier to implement than the current venous blood sampling techniques. This study investigates the diagnostic accuracy of the modified HEART score, integrating fingerstick POC troponin testing, in ruling out acute coronary syndrome (ACS).

Methods

The data of 96 patients with chest pain, included in a study investigating a novel POC troponin device under development at the cardiac emergency department, were analysed retrospectively. Based on the patients' admission data and capillary POC high-sensitivity troponin I (hs-cTnI) results, the modified HEART score was determined. The outcome measure, for evaluating the diagnostic accuracy of the modified HEART score, was the occurrence of ACS.

Results

Of the total study population, 33 patients (34%) were diagnosed with ACS. Seventeen patients (18%) were classified as low risk (0-3 points) and one patient (6%) in this group was diagnosed with ACS. The sensitivity and negative predictive value of the modified HEART score was 97.0 and 97.6%, respectively.

Conclusion

The modified HEART score, integrating capillary POC hs-cTnI results, is a promising tool for ruling out ACS in patients with chest pain presenting to the cardiac emergency department. These results encourage prospective investigation into the integration of fingerstick POC troponin testing in the modified HEART score in a pre-hospital setting.

SUBMITTER: Koper LH 

PROVIDER: S-EPMC9270546 | biostudies-literature | 2022 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

URGENT 1.5: diagnostic accuracy of the modified HEART score, with fingerstick point-of-care troponin testing, in ruling out acute coronary syndrome.

Koper L H LH   Frenk L D S LDS   Meeder J G JG   van Osch F H M FHM   Bruinen A L AL   Janssen M J W MJW   van 't Hof A W J AWJ   Rahel B M BM  

Netherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation 20211124 7-8


<h4>Background</h4>The HEART score is a validated risk stratification tool for chest pain patients presenting to the emergency department and was recently investigated for implementation in a pre-hospital setting. Fingerstick (capillary blood) point-of-care (POC) troponin testing enables quick measurements outside the hospital and seems easier to implement than the current venous blood sampling techniques. This study investigates the diagnostic accuracy of the modified HEART score, integrating f  ...[more]

Similar Datasets

| S-EPMC10985641 | biostudies-literature
| S-EPMC2657589 | biostudies-literature
| S-EPMC6519406 | biostudies-literature
| S-EPMC7141983 | biostudies-literature
| S-EPMC8766564 | biostudies-literature
| S-EPMC9213370 | biostudies-literature
| S-EPMC10255045 | biostudies-literature
| S-EPMC8552116 | biostudies-literature
| S-EPMC9349062 | biostudies-literature