Project description:High-throughput sequencing of the miRNAs present in plasma of COVID-19 patients at an early stage of the disease including non-SARS-CoV2 infected patients. This study allowed us to identify and functionally characterize human miRNAs associated with a worse evolution of the disease and a greater mortality. Samples were collected at hospital entry or within the first days after hospitalization and before treatment with immunotherapy for IL6 (e.g. Tocilizumab), interferon beta, corticoids and ribavirin, among others. Plasma samples were obtained from peripheral blood extracted in EDTA tubes after centrifugation. Total RNA, including small RNAs, was isolated from 400μl of plasma with the miRNeasy Serum Plasma Advanced kit (Qiagen). RNA quality and quantity were evaluated by the Bioanalyzer 2100 with Agilent RNA 6000 Nano Kit.
Project description:Exhaled breath condensate (EBC) is routinely collected and analyzed in breath research. Because it contains aerosol droplets, EBC samples from SARS-CoV-2 infected individuals harbor the virus and pose the threat of infectious exposure. We report for the first time a safe and consistent method to fully inactivate SARS-CoV-2 in EBC samples and make EBC samples safe for processing and analysis. EBC samples containing infectious SARS-CoV-2 were treated with several concentrations of acetonitrile. The most commonly used 10% acetonitrile treatment for EBC processing failed to completely inactivate the virus in samples and viable virus was detected by the assay of SARS-CoV-2 infection of Vero E6 cells in a biosafety level 3 laboratory. Treatment with either 50% or 90% acetonitrile was effective to completely inactivate the virus, resulting in safe, non-infectious EBC samples that can be used for metabolomic analysis. Our study provides SARS-CoV-2 inactivation protocol for the collection and processing of EBC samples in the clinical setting and for advancing to metabolic assessments in health and disease.
Project description:A new detection strategy was developed to improve the sensitivity of a lateral flow immunoassay platform utilizing a delayed hydrophobic barrier fabricated with trimethylsilyl cellulose (TMSC). The SARS-CoV-2 spike receptor-binding domain (SARS-CoV-2 SP RBD) antigen was chosen as a model analyte to demonstrate the superior detectability of this scheme. The novel device consists of 2 separate layers, so-called delayed lateral flow immunoassay (d-LFIA). The upper layer is intended for the analyte or sample flow path, where the test solution flows freely straight to the detection zone to bind with the primary antibody. The lower layer, located just underneath, is designed for the SARS-CoV-2 spike receptor-binding domain-conjugated gold nanoparticles (SARS-CoV-2 SP RBD-AuNPs) used for producing a colorimetric signal. This layer is fabricated with a TMSC barrier to time-delay the movement of SARS-CoV-2 SP RBD-AuNPs, thus allowing the antigen to bind with the primary antibody more efficiently. This platform exhibited a 2.6-fold enhancement in the sensitivity and 9.1-fold improvement in the limit of detection (LOD) as compared with the conventional LFIA. In addition, this d-LFIA device was satisfactorily applied to accurate screening of COVID-19 patients.
Project description:ObjectivesWe validate the use of a lateral flow immunoassay (LFI) intended for rapid screening and qualitative detection of anti-SARS-CoV-2 IgM and IgG in serum, plasma, and whole blood, and compare results with ELISA. We also seek to establish the value of LFI testing on blood obtained from a capillary blood sample.MethodsSamples collected by venous blood draw and finger stick were obtained from patients with SARS-CoV-2 detected by RT-qPCR and control patients. Samples were tested with Biolidics 2019-nCoV IgG/IgM Detection Kit lateral flow immunoassay, and antibody calls were compared with ELISA.ResultsBiolidics LFI showed clinical sensitivity of 92% with venous blood at 7 days after PCR diagnosis of SARS-CoV-2. Test specificity was 92% for IgM and 100% for IgG. There was no significant difference in detecting IgM and IgG with Biolidics LFI and ELISA at D0 and D7 (p = 1.00), except for detection of IgM at D7 (p = 0.04). Capillary blood of SARS-CoV-2 patients showed 93% sensitivity for antibody detection.ConclusionsClinical performance of Biolidics 2019-nCoV IgG/IgM Detection Kit is comparable to ELISA and was consistent across sample types. This provides an opportunity for decentralized rapid testing and may allow point-of-care and longitudinal self-testing for the presence of anti-SARS-CoV-2 antibodies.
Project description:IntroductionDigital immunoassays are generally regarded as superior tests for the detection of infectious disease pathogens, but there have been insufficient data concerning SARS-CoV-2 immunoassays.MethodsWe prospectively evaluated a novel digital immunoassay (RapidTesta SARS-CoV-2). Two nasopharyngeal samples were simultaneously collected for antigen tests and Real-time RT-PCR.ResultsDuring the study period, 1127 nasopharyngeal samples (symptomatic patients: 802, asymptomatic patients: 325) were evaluated. For digital immunoassay antigen tests, the sensitivity was 78.3% (95% CI: 67.3%-87.1%) and the specificity was 97.6% (95% CI: 96.5%-98.5%). When technicians visually analyzed the antigen test results, the sensitivity was 71.6% (95% CI: 59.9%-81.5%) and the specificity was 99.2% (95% CI: 98.5%-99.7%). Among symptomatic patients, the sensitivity was 89.4% (95% CI; 76.9%-96.5%) with digital immunoassay antigen tests, and 85.1% (95% CI; 71.7%-93.8%) with visually analyzed the antigen test, respectively.ConclusionsThe sensitivity of digital immunoassay antigen tests was superior to that of visually analyzed antigen tests, but the rate of false-positive results increased with the introduction of a digital immunoassay device.
Project description:Due to the severity of COVID-19 disease, the U.S. Centers for Disease Control and Prevention and World Health Organization recommend that manipulation of active viral cultures of SARS-CoV-2 and respiratory secretions from COVID-19 patients be performed in biosafety level (BSL)3 laboratories. Therefore, it is imperative to develop viral inactivation procedures that permit samples to be transferred to lower containment levels (BSL2), while maintaining the fidelity of complex downstream assays to expedite the development of medical countermeasures. In this study, we demonstrate optimal conditions for complete viral inactivation following fixation of infected cells with commonly used reagents for flow cytometry, UVC inactivation in sera and respiratory secretions for protein and Ab detection, heat inactivation following cDNA amplification for droplet-based single-cell mRNA sequencing, and extraction with an organic solvent for metabolomic studies. Thus, we provide a suite of viral inactivation protocols for downstream contemporary assays that facilitate sample transfer to BSL2, providing a conceptual framework for rapid initiation of high-fidelity research as the COVID-19 pandemic continues.
Project description:Antibody assay for SARS-CoV-2 has become increasingly important to track latent and asymptomatic infections, check the individual's immune status, and confirm vaccine efficacy and durability. However, current SARS-CoV-2 antibody assays require invasive blood collection, requiring a remote laboratory and a trained phlebotomist. Direct detection of SARS-CoV-2 antibodies from clinical saline gargle samples has been considered challenging due to the smaller number of antibodies in such specimens and the high limit of detection of currently available rapid tests. This work demonstrates simple and non-invasive methods for detecting SARS-CoV-2 salivary antibodies. Competitive particle immunoassays were developed on a paper microfluidic chip using the receptor-binding domain (RBD) antigens on spike proteins. Using a smartphone, they were monitored by counting the captured fluorescent particles or evaluating the capillary flow velocities. The limit of detection (LOD), cross-binding between alpha- and omicron-strains, and the effect of angiotensin-converting enzyme 2 (ACE2) presence were investigated. LODs were 1-5 ng/mL in both 10% and 1% saliva. Clinical saline gargle samples were assayed using both methods, showing a statistical difference between virus-negative and virus-positive samples, although the assays targeted antibodies. Only a small number of virus-positive samples were antibody-negative. The high assay sensitivity detected a small number of antibodies developed even during the early phase of infections. Overall, this work demonstrates the ability to detect SARS-CoV-2 salivary IgG antibodies on simple, cost-effective, portable platforms towards mitigating SARS-CoV-2 and potentially other respiratory viruses.
Project description:The early diagnosis of Coronavirus disease (COVID-19) requires either an accurate detection of genetic material or a sensitive detection of viral proteins. In this work, we designed an immunoassay platform for detecting trace levels of SARS-CoV-2 spike (S) protein. It is based on surface-enhanced resonance Raman scattering (SERRS) of methylene blue (MB) adsorbed onto spherical gold nanoparticles (AuNPs) and coated with a 6 nm silica shell. The latter shell in the SERRS nanoprobe prevented aggregation and permitted functionalization with SARS-CoV-2 antibodies. Specificity of the immunoassay was achieved by combining this functionalization with antibody immobilization on the cover slides that served as the platform support. Different concentrations of SARS-CoV-2 antigen could be distinguished and the lack of influence of interferents was confirmed by treating SERRS data with the multidimensional projection technique Sammon's mapping. With SERRS using a laser line at 633 nm, the lowest concentration of spike protein detected was 10 pg/mL, achieving a limit of detection (LOD) of 0.046 ng/mL (0.60 pM). This value is comparable to the lowest concentrations in the plasma of COVID-19 patients at the onset of symptoms, thus indicating that the SERRS immunoassay platform may be employed for early diagnosis.
Project description:Dried blood spot samples (DBS) provide an alternative sample type to venous blood samples for antibody testing. DBS are used by NHS for diagnosing Hepatitis C and by Public Health England for large scale HIV and Hepatitis C serosurveillance; the applicability of DBS based approaches for SARS-CoV-2 antibody detection is uncertain. The study aimed to compare antibody detection in DBS eluates using the Roche Elecsys ® immunoassay with antibody detection in paired plasma samples, using the same assay. The study was in one Police and one Fire & Rescue facility in England; it comprised of 195 participants within a larger sample COVID-19 serodiagnostics study of keyworkers, EDSAB-HOME. Outcome measures were sensitivity and specificity of DBS (the index test) relative to plasma (the reference test), at an experimental cut-off; quality of DBS sample collected; estimates of relative sensitivity of DBS vs. plasma immunoassay in a larger population. 18/195 (9.2%) participants tested positive using plasma samples. DBS sample quality varied markedly by phlebotomist, and low sample volume significantly reduced immunoassay signals. Using an experimental cut-off, sensitivity and specificity of DBS were 89.0% (95% CI 67.2, 96.9%) and 100.0% (95% CI 97.9, 100%) respectively compared with using plasma. The limit of detection for DBS is about 30 times higher than for plasma. DBS use for SARS-CoV-2 serology, though feasible, is insensitive relative to immunoassays on plasma. Sample quality impacts on assay performance. Alternatives, including the collection of capillary blood samples, should be considered for screening programs.