Unknown

Dataset Information

0

Packed-Fiber Solid Phase-Extraction Coupled with HPLC-MS/MS for Rapid Determination of Lipid Oxidative Damage Biomarker 8-Iso-Prostaglandin F in Urine.


ABSTRACT: The 8-iso-prostaglandin F (8-iso-PGF) biomarker is used as the gold standard for tracing lipid oxidative stress in vivo. The analysis of urinary 8-iso-PGF is challenging when dealing with trace amounts of 8-iso-PGF and the complexity of urine matrixes. A packed-fiber solid-phase extraction (PFSPE)-coupled with HPLC-MS/MS-method, based on polystyrene (PS)-electrospun nanofibers, was developed for the specific determination of 8-iso-PGF in urine and compared with other newly developed LC-MS/MS methods. The method, which simultaneously processed 12 samples within 5 min on a self-made semi-automatic array solid-phase extraction processor, was the first to introduce PS-electrospun nanofibers as an adsorbent for the extraction of 8-iso-PGF and was successfully applied to real urine samples. After optimizing the PFSPE conditions, good linearity in the range of 0.05-5 ng/mL with R2 > 0.9996 and a satisfactory limit of detection of 0.015 ng/mL were obtained, with good intraday and interday precision (RSD < 10%) and recoveries of 95.3-103.8%. This feasible method is expected to be used for the batch quantitative analysis of urinary 8-iso-PGF.

SUBMITTER: Sun Y 

PROVIDER: S-EPMC9318247 | biostudies-literature | 2022 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Packed-Fiber Solid Phase-Extraction Coupled with HPLC-MS/MS for Rapid Determination of Lipid Oxidative Damage Biomarker 8-Iso-Prostaglandin F<sub>2α</sub> in Urine.

Sun Ying Y   Yan Yan Y   Kang Xuejun X  

Molecules (Basel, Switzerland) 20220710 14


The 8-iso-prostaglandin F2α (8-iso-PGF2α) biomarker is used as the gold standard for tracing lipid oxidative stress in vivo. The analysis of urinary 8-iso-PGF2α is challenging when dealing with trace amounts of 8-iso-PGF2α and the complexity of urine matrixes. A packed-fiber solid-phase extraction (PFSPE)−coupled with HPLC-MS/MS−method, based on polystyrene (PS)-electrospun nanofibers, was developed for the specific determination of 8-iso-PGF2α in urine and compared with other newly developed LC  ...[more]

Similar Datasets

| S-EPMC6260378 | biostudies-literature
| S-EPMC6626672 | biostudies-literature
| S-EPMC4929888 | biostudies-literature
| S-EPMC11539727 | biostudies-literature
| S-EPMC5098214 | biostudies-literature
| S-EPMC8948878 | biostudies-literature
| S-EPMC8038327 | biostudies-literature
| S-EPMC4301581 | biostudies-other
| S-EPMC3934528 | biostudies-literature
| S-EPMC7076633 | biostudies-literature