Unknown

Dataset Information

0

Evaluation of infarct core and ischemic penumbra by absolute quantitative cerebral dynamic susceptibility contrast perfusion magnetic resonance imaging using self-calibrated echo planar imaging sequencing in patients with acute ischemic stroke.


ABSTRACT:

Background

It has been hypothesized that an absolute quantitative dynamic susceptibility contrast (DSC) cerebral perfusion-weighted imaging (PWI) technique based on self-calibrated echo-planar imaging (EPI) could be a reliable measurement of quantitative cerebral blood flow (qCBF) and quantitative cerebral blood volume (qCBV). This study aimed to investigate the clinical value of this technique in offering a unique insight into ischemic stroke (IS) pathophysiology and improving the sensitivity of IS diagnosis.

Methods

A total of 14 patients with IS who underwent routine magnetic resonance imaging (MRI) and Self-CALibrated EPI Perfusion-Weighted Imaging (SCALE-PWI) scanning were prospectively recruited as a consecutive convenience sample. qCBF and qCBV maps were processed immediately online after the scan. Then, 2 radiologists independently drew the region of interest (ROI) of the infarct core, ischemic penumbra, and the contralateral normal tissues on each map for the statistical analyses. The paired-samples t-test, Wilcoxon signed-rank test, independent-samples t-test, and receiver operating characteristic (ROC) curve were performed. A value of P<0.05 was considered statistically significant with 95% confidence intervals (CI).

Results

All the values of qCBF and qCBV in the lesions were lower than those in the contralateral normal tissues (all P<0.05). The values of qCBF and qCBV in the infarct core were lower than those in the ischemic penumbra (mean values: 16.42 vs. 21.54 mL/100 g/min, P=0.013; 1.23 vs. 1.47 mL/100 g, P=0.049, respectively). The qCBF threshold of the infarct core was 18.18 mL/100 g/min (sensitivity, 71.40%; specificity, 64.30%) and the qCBF threshold of the ischemic penumbra was 28.09 mL/100 g/min (sensitivity, 78.60%; specificity, 85.70%).

Conclusions

Different from the previous semi-quantitative measurement, the SCALE-PWI technique has the potential to provide absolute quantitative hemodynamic information which may be used to detect the infarct core and ischemic penumbra in a relatively short scan time.

SUBMITTER: Ma X 

PROVIDER: S-EPMC9338368 | biostudies-literature | 2022 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of infarct core and ischemic penumbra by absolute quantitative cerebral dynamic susceptibility contrast perfusion magnetic resonance imaging using self-calibrated echo planar imaging sequencing in patients with acute ischemic stroke.

Ma Xiaoyue X   Wang Yan Y   Wang Mengke M   Zhang Menghuan M   Meng Nan N   Zhang Long L   Zhang Jinlong J   Dou Shewei S   Wang Meiyun M  

Quantitative imaging in medicine and surgery 20220801 8


<h4>Background</h4>It has been hypothesized that an absolute quantitative dynamic susceptibility contrast (DSC) cerebral perfusion-weighted imaging (PWI) technique based on self-calibrated echo-planar imaging (EPI) could be a reliable measurement of quantitative cerebral blood flow (qCBF) and quantitative cerebral blood volume (qCBV). This study aimed to investigate the clinical value of this technique in offering a unique insight into ischemic stroke (IS) pathophysiology and improving the sensi  ...[more]

Similar Datasets

| S-EPMC6495880 | biostudies-literature
| S-EPMC6435385 | biostudies-literature
| S-EPMC9406974 | biostudies-literature
| S-EPMC10380847 | biostudies-literature
| S-EPMC6527337 | biostudies-literature
| S-EPMC8349868 | biostudies-literature
| S-EPMC5313515 | biostudies-literature
| S-EPMC9475395 | biostudies-literature
| S-EPMC8616809 | biostudies-literature
| S-EPMC5836862 | biostudies-literature