Unknown

Dataset Information

0

Value of 3D printing technology combined with indocyanine green fluorescent navigation in complex laparoscopic hepatectomy.


ABSTRACT:

Background

Laparoscopic hepatectomy (LH) has achieved rapid progress over the last decade. However, it is still challenging to apply laparoscopy to lesions located in segments I, VII, VIII, and IVa and the hepatic hilar region due to difficulty operating around complex anatomical structures. In this study, we applied three-dimensional printing (3DP) and indocyanine green (ICG) fluorescence imaging technology to complex laparoscopic hepatectomy (CLH) to explore the effects and value of the modified procedure.

Materials and methods

From January 2019 to January 2021, 54 patients with complex hepatobiliary diseases underwent LH at our center. Clinical data were collected from these patients and retrospectively analyzed.

Results

A total of 30 patients underwent CLH using the conventional approach, whereas 24 cases received CLH with 3DP technology and ICG fluorescent navigation. Preoperative data were compared between the two groups. In the 3DP group, we modified the surgical strategy of four patients (4/24, 16.7%) due to real-time intraoperative navigation with 3DP and ICG fluorescent imaging technology. We did not modify the surgical strategy for any patient in the non-3DP group (P = 0.02). There were no significant differences between the non-3DP and 3DP groups regarding operating time (297.7±104.1 min vs. 328.8±110.9 min, P = 0.15), estimated blood loss (400±263.8 ml vs. 345.8±356.1 ml, P = 0.52), rate of conversion to laparotomy (3/30 vs. 2/24, P = 0.79), or pathological outcomes including the incidence of microscopical R0 margins (28/30 vs. 24/24, P = 0.57). Additionally, there were no significant differences in postoperative complications or recovery conditions between the two groups. No instances of 30- or 90-day mortality were observed.

Conclusion

The optimal surgical strategy for CLH can be chosen with the help of 3DP technology and ICG fluorescent navigation. This modified procedure is both safe and effective, but without improvement of intraoperative and short-term outcomes.

SUBMITTER: Cheng J 

PROVIDER: S-EPMC9371281 | biostudies-literature | 2022

REPOSITORIES: biostudies-literature

altmetric image

Publications

Value of 3D printing technology combined with indocyanine green fluorescent navigation in complex laparoscopic hepatectomy.

Cheng Jian J   Wang Zhifei Z   Liu Jie J   Dou Changwei C   Yao Weifeng W   Zhang Chengwu C  

PloS one 20220811 8


<h4>Background</h4>Laparoscopic hepatectomy (LH) has achieved rapid progress over the last decade. However, it is still challenging to apply laparoscopy to lesions located in segments I, VII, VIII, and IVa and the hepatic hilar region due to difficulty operating around complex anatomical structures. In this study, we applied three-dimensional printing (3DP) and indocyanine green (ICG) fluorescence imaging technology to complex laparoscopic hepatectomy (CLH) to explore the effects and value of th  ...[more]

Similar Datasets

| S-EPMC8055570 | biostudies-literature
| S-EPMC11190512 | biostudies-literature
| S-EPMC9343849 | biostudies-literature
| S-EPMC5638993 | biostudies-literature
| S-EPMC9165200 | biostudies-literature
| S-EPMC8523512 | biostudies-literature
| S-EPMC7750833 | biostudies-literature
| S-EPMC6701684 | biostudies-literature
| S-EPMC6260439 | biostudies-literature