Electrochemical Biosensor for SARS-CoV-2 cDNA Detection Using AuPs-Modified 3D-Printed Graphene Electrodes.


ABSTRACT: A low-cost and disposable graphene polylactic (G-PLA) 3D-printed electrode modified with gold particles (AuPs) was explored to detect the cDNA of SARS-CoV-2 and creatinine, a potential biomarker for COVID-19. For that, a simple, non-enzymatic electrochemical sensor, based on a Au-modified G-PLA platform was applied. The AuPs deposited on the electrode were involved in a complexation reaction with creatinine, resulting in a decrease in the analytical response, and thus providing a fast and simple electroanalytical device. Physicochemical characterizations were performed by SEM, EIS, FTIR, and cyclic voltammetry. Square wave voltammetry was employed for the creatinine detection, and the sensor presented a linear response with a detection limit of 0.016 mmol L-1. Finally, a biosensor for the detection of SARS-CoV-2 was developed based on the immobilization of a capture sequence of the viral cDNA upon the Au-modified 3D-printed electrode. The concentration, immobilization time, and hybridization time were evaluated in presence of the DNA target, resulting in a biosensor with rapid and low-cost analysis, capable of sensing the cDNA of the virus with a good limit of detection (0.30 µmol L-1), and high sensitivity (0.583 µA µmol-1 L). Reproducible results were obtained (RSD = 1.14%, n = 3), attesting to the potentiality of 3D-printed platforms for the production of biosensors.

SUBMITTER: Silva LRG 

PROVIDER: S-EPMC9405530 | biostudies-literature | 2022 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Electrochemical Biosensor for SARS-CoV-2 cDNA Detection Using AuPs-Modified 3D-Printed Graphene Electrodes.

Silva Luiz R G LRG   Stefano Jéssica S JS   Orzari Luiz O LO   Brazaca Laís C LC   Carrilho Emanuel E   Marcolino-Junior Luiz H LH   Bergamini Marcio F MF   Munoz Rodrigo A A RAA   Janegitz Bruno C BC  

Biosensors 20220810 8


A low-cost and disposable graphene polylactic (G-PLA) 3D-printed electrode modified with gold particles (AuPs) was explored to detect the cDNA of SARS-CoV-2 and creatinine, a potential biomarker for COVID-19. For that, a simple, non-enzymatic electrochemical sensor, based on a Au-modified G-PLA platform was applied. The AuPs deposited on the electrode were involved in a complexation reaction with creatinine, resulting in a decrease in the analytical response, and thus providing a fast and simple  ...[more]

Similar Datasets

| S-EPMC9142345 | biostudies-literature
| S-EPMC9057201 | biostudies-literature
| S-EPMC7146522 | biostudies-literature
| S-EPMC8433388 | biostudies-literature
| S-EPMC9529345 | biostudies-literature
| S-EPMC4455289 | biostudies-literature
| S-EPMC8534075 | biostudies-literature
| S-EPMC3379819 | biostudies-literature
| S-EPMC11307982 | biostudies-literature
| S-EPMC9245948 | biostudies-literature