ABSTRACT: Background
Liver transplantation (LTx) is the only treatment option for patients with end-stage liver disease. Novel organ preservation techniques such as hypothermic machine perfusion (HMP) or normothermic machine perfusion (NMP) are under investigation in order to improve organ quality from extended criteria donors and donors after circulatory death. The aim of this study was to systematically review the literature reporting LTx outcomes using NMP or HMP compared to static cold storage (SCS).Methods
The following data were retrieved: graft primary nonfunction rate, early allograft dysfunction (EAD) rate, biliary complication rate, and 12-month graft and patient survival. A total of 15 studies were included (6 NMP and 9 HMP studies), and meta-analysis was performed only for HMP studies because NMP had considerable differences.Results
The systematic review showed the potential of NMP to reduce graft injury and lower the liver graft discard rate. The performed quantitative analyses showed that the use of HMP reduces the rate of EAD (odds ratio [OR] 0.51; 95% confidence interval [CI] 0.34-0.76; p = 0.001; I 2 = 0%) and non-anastomotic biliary strictures (OR 0.34; 95% CI 0.17-0.67; p = 0.002; I 2 = 0%) compared to SCS.Conclusion
Our systematic review and meta-analysis revealed that the use of HMP reduces the rate of EAD and non-anastomotic biliary strictures compared to SCS.
SUBMITTER: Jakubauskas M
PROVIDER: S-EPMC9421699 | biostudies-literature | 2022 Aug
REPOSITORIES: biostudies-literature
Jakubauskas Matas M Jakubauskiene Lina L Leber Bettina B Strupas Kestutis K Stiegler Philipp P Schemmer Peter P
Visceral medicine 20211108 4
<h4>Background</h4>Liver transplantation (LTx) is the only treatment option for patients with end-stage liver disease. Novel organ preservation techniques such as hypothermic machine perfusion (HMP) or normothermic machine perfusion (NMP) are under investigation in order to improve organ quality from extended criteria donors and donors after circulatory death. The aim of this study was to systematically review the literature reporting LTx outcomes using NMP or HMP compared to static cold storage ...[more]