Reconstruction of Mandibular Contour Defect Using Patient-Specific Titanium Implant Manufactured by Selective Laser Melting Method.


ABSTRACT:

Abstract

The purpose of this study was to evaluate the surgical accuracy and postoperative stability of patient-specific titanium implants (PSTIs) manufactured by the selective laser melting method and applied for mandibular contour reconstruction. For 2 patients who showed asymmetry of the mandibular angle after mandibuloplasty, including angle reduction, reconstructive surgeries of the mandibular contour defects were performed using PSTI. Patient-specific titanium implant was three-dimensional designed using a mirror image similar to the shape of the contralateral side, and 3 screw holes were formed, avoiding the inferior alveolar nerve. Patient-specific titanium implant was applied intraorally, and screw fixation was performed via a transbuccal approach. Surgical accuracy and postoperative stability were evaluated by comparing preoperative three-dimensional design with immediate postoperative computed tomography (CT), and immediate postoperative CT with postoperative 6-month CT, respectively. Both patients were satisfied with the surgical results, and no complications were observed. Surgical accuracy was defined as a mean Hausdorff distance <0.4mm, and postoperative stability was defined as a mean Hausdorff distance <0.3mm. Our results suggest that PSTI by the selective laser melting method for augmentation of the mandibular border is useful as an additional cosmetic surgery.

SUBMITTER: Yang HJ 

PROVIDER: S-EPMC9518971 | biostudies-literature | 2022 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Reconstruction of Mandibular Contour Defect Using Patient-Specific Titanium Implant Manufactured by Selective Laser Melting Method.

Yang Hoon Joo HJ   Oh Ji Hye JH  

The Journal of craniofacial surgery 20220223 7


<h4>Abstract</h4>The purpose of this study was to evaluate the surgical accuracy and postoperative stability of patient-specific titanium implants (PSTIs) manufactured by the selective laser melting method and applied for mandibular contour reconstruction. For 2 patients who showed asymmetry of the mandibular angle after mandibuloplasty, including angle reduction, reconstructive surgeries of the mandibular contour defects were performed using PSTI. Patient-specific titanium implant was three-dim  ...[more]

Similar Datasets

| S-EPMC6117799 | biostudies-other
| S-EPMC5455917 | biostudies-other
| S-EPMC7560194 | biostudies-literature
| S-EPMC8631384 | biostudies-literature
| S-EPMC9686285 | biostudies-literature
| S-EPMC6316947 | biostudies-other
| S-EPMC7229066 | biostudies-literature
| S-EPMC7870834 | biostudies-literature
| S-EPMC5448875 | biostudies-other
| S-EPMC6128459 | biostudies-literature