Clinical outcomes after permanent polymer or polymer-free stent implantation in patients with diabetes mellitus: The ReCre8 diabetes substudy.


ABSTRACT:

Objectives

The purpose of this analysis was to compare target-lesion failure (TLF) of a permanent polymer zotarolimus-eluting stent (PP-ZES) versus a polymer-free amphilimus-eluting stent (PF-AES) in diabetics.

Background

The improvement of outcomes with new-generation drug-eluting stent as seen in the general population is less pronounced among diabetics. The PF-AES introduces an elution-technology with potential enhanced performance in diabetics.

Methods

In this subanalysis of the ReCre8 trial, patients were randomized to either a PP-ZES or PF-AES after stratification for diabetes and troponin status. The primary device-oriented endpoint was TLF, a composite of cardiac death, target-vessel myocardial infarction and target-lesion revascularization.

Results

In the ReCre8 trial, 304 (20%) patients were diabetic and 96 (6%) had insulin-dependent diabetes mellitus. There was no statistically significant difference between the two study arms regarding the primary endpoint (PP-ZES 7.2% vs. PF-AES 4.0%; p = .21), although the composite of net adverse clinical events was higher in the PP-ZES arm (15.7 vs. 8.0%; p = .035). Stent thrombosis was low in both groups with no cases in the PP-ZES arm and 1 case in the PF-AES arm (p = .32). Regarding insulin-treated diabetics, TLF was higher in the PP-ZES arm (14.9 vs. 2.1%; p = .022).

Conclusions

Diabetics could potentially benefit from a dedicated stent, releasing sirolimus with a lipophilic carrier (amphilimus-formulation). Future trials should confirm the potential benefit of a PF-AES in this population.

SUBMITTER: van Hemert ND 

PROVIDER: S-EPMC9540458 | biostudies-literature | 2022 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Clinical outcomes after permanent polymer or polymer-free stent implantation in patients with diabetes mellitus: The ReCre8 diabetes substudy.

van Hemert Nicole D ND   Rozemeijer Rik R   Voskuil Michiel M   Stein Mèra M   Frambach Peter P   Rittersma Saskia Z SZ   Kraaijeveld Adriaan O AO   Leenders Geert E H GEH   van der Harst Pim P   Agostoni Pierfrancesco P   Stella Pieter R PR  

Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions 20210403 2


<h4>Objectives</h4>The purpose of this analysis was to compare target-lesion failure (TLF) of a permanent polymer zotarolimus-eluting stent (PP-ZES) versus a polymer-free amphilimus-eluting stent (PF-AES) in diabetics.<h4>Background</h4>The improvement of outcomes with new-generation drug-eluting stent as seen in the general population is less pronounced among diabetics. The PF-AES introduces an elution-technology with potential enhanced performance in diabetics.<h4>Methods</h4>In this subanalys  ...[more]

Similar Datasets

| S-EPMC8477883 | biostudies-literature
| S-EPMC7531093 | biostudies-literature
| S-EPMC6957170 | biostudies-literature
| S-EPMC10520042 | biostudies-literature
| S-EPMC5518142 | biostudies-other
| S-EPMC10679460 | biostudies-literature
| S-EPMC4118223 | biostudies-literature
| S-EPMC11631268 | biostudies-literature
| S-EPMC11307809 | biostudies-literature
| S-EPMC6324315 | biostudies-literature