Determination of Carbonyl Compounds in Different Work Environments: Comparison between LC-UV/DAD and LC-MS/MS Detection Methods.


ABSTRACT: There were two analytical methods for the determination of 12 carbonyl compounds (CCs) by using liquid chromatography (LC) coupled with mass spectrometry (MS/MS) and diode array detector (UV/DAD) that were developed and applied to 52 samples that were collected in 10 workplaces. Linearity (0.996 < R2 < 0.999), intra-day repeatability (0.7 < RSD% < 10), and inter-day repeatability (5 < RSD% < 16) were acceptable for both techniques, but the highest sensibility of the MS/MS method allowed us to correctly quantify 98% of the samples (versus 32% by UV/DAD). The comparison of the concentrations that were obtained by quantifying the same sample with both techniques showed good agreement for acetaldehyde and formaldehyde (0.1 < % deviation < 30) but much higher for the less abundant congeners. In real samples, formaldehyde was the most abundant congener (concentrations between 2.7 and 77 µg m-3), followed by acetaldehyde (concentrations between 1.5 and 79 µg m-3) and butyraldehyde (concentrations between 0.4 and 13 µg m-3). In all the beauty salon samples, instead, the most abundant congener was acetaldehyde (concentrations between 19 and 79 µg m-3), probably associated with the use of beauty products. Principal components analysis (PCA) confirms the ubiquitous character of formaldehyde and highlights the influence of minority CCs on different workplaces.

SUBMITTER: Castellani F 

PROVIDER: S-EPMC9565147 | biostudies-literature | 2022 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Determination of Carbonyl Compounds in Different Work Environments: Comparison between LC-UV/DAD and LC-MS/MS Detection Methods.

Castellani Federica F   Antonucci Arianna A   Pindinello Ivano I   Protano Carmela C   Vitali Matteo M  

International journal of environmental research and public health 20220923 19


There were two analytical methods for the determination of 12 carbonyl compounds (CCs) by using liquid chromatography (LC) coupled with mass spectrometry (MS/MS) and diode array detector (UV/DAD) that were developed and applied to 52 samples that were collected in 10 workplaces. Linearity (0.996 < R<sup>2</sup> < 0.999), intra-day repeatability (0.7 < RSD% < 10), and inter-day repeatability (5 < RSD% < 16) were acceptable for both techniques, but the highest sensibility of the MS/MS method allow  ...[more]

Similar Datasets

| S-EPMC6100578 | biostudies-literature
| S-EPMC6269983 | biostudies-literature
| S-EPMC9600761 | biostudies-literature
| S-EPMC4129172 | biostudies-literature
| S-EPMC8912889 | biostudies-literature
| S-EPMC6303014 | biostudies-literature
| S-EPMC3875626 | biostudies-literature
| S-EPMC8541004 | biostudies-literature
| S-EPMC4395275 | biostudies-literature
| S-EPMC7999497 | biostudies-literature