Evaluation of radiomics feature stability in abdominal monoenergetic photon counting CT reconstructions.


ABSTRACT: Feature stability and standardization remain challenges that impede the clinical implementation of radiomics. This study investigates the potential of spectral reconstructions from photon-counting computed tomography (PCCT) regarding organ-specific radiomics feature stability. Abdominal portal-venous phase PCCT scans of 10 patients in virtual monoenergetic (VM) (keV 40-120 in steps of 10), polyenergetic, virtual non-contrast (VNC), and iodine maps were acquired. Two 2D and 3D segmentations measuring 1 and 2 cm in diameter of the liver, lung, spleen, psoas muscle, subcutaneous fat, and air were obtained for spectral reconstructions. Radiomics features were extracted with pyradiomics. The calculation of feature-specific intraclass correlation coefficients (ICC) was performed by comparing all segmentation approaches and organs. Feature-wise and organ-wise correlations were evaluated. Segmentation-resegmentation stability was evaluated by concordance correlation coefficient (CCC). Compared to non-VM, VM-reconstruction features tended to be more stable. For VM reconstructions, 3D 2 cm segmentation showed the highest average ICC with 0.63. Based on a criterion of ≥ 3 stable organs and an ICC of ≥ 0.75, 12-mainly non-first-order features-are shown to be stable between the VM reconstructions. In a segmentation-resegmentation analysis in 3D 2 cm, three features were identified as stable based on a CCC of > 0.6 in ≥ 3 organs in ≥ 6 VM reconstructions. Certain radiomics features vary between monoenergetic reconstructions and depend on the ROI size. Feature stability was also shown to differ between different organs. Yet, glcm_JointEntropy, gldm_GrayLevelNonUniformity, and firstorder_Entropy could be identified as features that could be interpreted as energy-independent and segmentation-resegmentation stable in this PCCT collective. PCCT may support radiomics feature standardization and comparability between sites.

SUBMITTER: Tharmaseelan H 

PROVIDER: S-EPMC9665022 | biostudies-literature | 2022 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of radiomics feature stability in abdominal monoenergetic photon counting CT reconstructions.

Tharmaseelan Hishan H   Rotkopf Lukas T LT   Ayx Isabelle I   Hertel Alexander A   Nörenberg Dominik D   Schoenberg Stefan O SO   Froelich Matthias F MF  

Scientific reports 20221115 1


Feature stability and standardization remain challenges that impede the clinical implementation of radiomics. This study investigates the potential of spectral reconstructions from photon-counting computed tomography (PCCT) regarding organ-specific radiomics feature stability. Abdominal portal-venous phase PCCT scans of 10 patients in virtual monoenergetic (VM) (keV 40-120 in steps of 10), polyenergetic, virtual non-contrast (VNC), and iodine maps were acquired. Two 2D and 3D segmentations measu  ...[more]

Similar Datasets

| S-EPMC11592515 | biostudies-literature
| S-EPMC10289937 | biostudies-literature
| S-EPMC10597903 | biostudies-literature
| S-EPMC9222087 | biostudies-literature
| S-EPMC9141463 | biostudies-literature
| S-EPMC11386360 | biostudies-literature
| S-EPMC10867981 | biostudies-literature
| S-EPMC10766624 | biostudies-literature
| S-EPMC9213380 | biostudies-literature
| S-EPMC10968735 | biostudies-literature