Unknown

Dataset Information

0

Biodegradable polymer-coated versus durable polymer-coated sirolimus-eluting stents: the final 5-year outcomes of the I-LOVE-IT 2 trial.


ABSTRACT:

Aims

This analysis presents the final five-year results of the I-LOVE-IT 2 trial, a non-inferiority study comparing a biodegradable polymer (BP) sirolimus-eluting stent (SES) with a durable polymer (DP) SES in patients with coronary artery disease.

Methods and results

Overall, 2,737 Chinese patients eligible for coronary stenting were treated with BP-SES or DP-SES in a 2:1 ratio. Patients who were randomised to the BP-SES group were additionally re-randomised to receive either six-month or 12-month dual antiplatelet therapy (DAPT) in a 1:1 ratio. The primary endpoint was 12-month target lesion failure (TLF: cardiac death, target vessel myocardial infarction (MI), or clinically indicated target lesion revascularisation). At five years, the overall follow-up rate was 90.8%, and the cumulative incidence of TLF as the primary endpoint was similar between BP-SES and DP-SES (hazard ratio [HR] 1.01, 95% confidence interval [CI]: 0.79 to 1.28), as was that for the patient-oriented composite endpoint (PoCE: all-cause death, all MI and any revascularisation) (HR 1.03, 95% CI: 0.86 to 1.23), or definite/probable stent thrombosis (ST) (HR 0.91, 95% CI: 0.70 to 1.77). Cumulative events were also similar between the six-month DAPT and 12-month DAPT groups after BP-SES implantation.

Conclusions

I-LOVE-IT 2 showed that the five-year safety and efficacy of BP-SES and DP-SES were similar, as were those between six months and 12 months of DAPT after BP-SES implantation.

SUBMITTER: Xu K 

PROVIDER: S-EPMC9724888 | biostudies-literature | 2021 Apr

REPOSITORIES: biostudies-literature

altmetric image

Publications

Biodegradable polymer-coated versus durable polymer-coated sirolimus-eluting stents: the final 5-year outcomes of the I-LOVE-IT 2 trial.

Xu Kai K   Xu Bo B   Guan Changdong C   Jing Quanmin Q   Zheng Qiangsun Q   Li Xueqi X   Zhao Xianxian X   Wang Haichang H   Zhao Xuezhong X   Li Yi Y   Li Jing J   Yang Yuejin Y   Han Yaling Y  

EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology 20210402 18


<h4>Aims</h4>This analysis presents the final five-year results of the I-LOVE-IT 2 trial, a non-inferiority study comparing a biodegradable polymer (BP) sirolimus-eluting stent (SES) with a durable polymer (DP) SES in patients with coronary artery disease.<h4>Methods and results</h4>Overall, 2,737 Chinese patients eligible for coronary stenting were treated with BP-SES or DP-SES in a 2:1 ratio. Patients who were randomised to the BP-SES group were additionally re-randomised to receive either six  ...[more]

Similar Datasets

| S-EPMC6915288 | biostudies-literature
| S-EPMC9904377 | biostudies-literature
| S-EPMC5552220 | biostudies-literature
| S-EPMC11877205 | biostudies-literature
| S-EPMC6310072 | biostudies-literature
| S-EPMC3823917 | biostudies-literature
| S-EPMC10405989 | biostudies-literature
| S-EPMC7552849 | biostudies-literature
| S-EPMC10018292 | biostudies-literature
| S-EPMC3898413 | biostudies-literature