A Feasibility Study for Immediate Histological Assessment of Various Skin Biopsies Using Ex Vivo Confocal Laser Scanning Microscopy.


ABSTRACT:

Background

Digitally stained ex vivo confocal laser scanning microscopy (CLSM) scans are a possible alternative to formalin-fixed and paraffin-embedded (FFPE) and hematoxylin-eosin (H&E) stained slides. This study explores the diagnostic accuracy of digitally-stained CLSM scans in comparison to H&E-stained slides in various dermatologic diseases in a real-life setting.

Methods

Samples of patients out of one selected dermatologic office were primarily scanned via CLSM; a diagnosis was made afterwards using FFPE- and H&E-stained slides by two experienced dermatopathologists. Primary outcomes were sensitivity and specificity of diagnosis in digitally stained CLSM scans in three separate diagnostic groups.

Results

CLSM evaluation of epithelial tumors (n = 132) demonstrated a sensitivity of 64.3%/83.9% and a specificity of 84.2%/71.1%. Diagnosis of melanocytic tumors (n = 86) showed a sensitivity of 19.1%/85.1% and a specificity of 96.3%/66.7%. In the diagnosis of other tumors/cysts and inflammatory dermatoses (n = 42), a sensitivity of 96.4%/96.8% and a specificity of 57.1%/45.5% was reached.

Conclusions

This study shows the possibilities and limitations of a broad use of CLSM. Because of a partly low diagnostic accuracy, such an application does not seem to be recommendable at present for every indication.

SUBMITTER: Ogrzewalla H 

PROVIDER: S-EPMC9777122 | biostudies-literature | 2022 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

A Feasibility Study for Immediate Histological Assessment of Various Skin Biopsies Using Ex Vivo Confocal Laser Scanning Microscopy.

Ogrzewalla Hanna H   Möhrle Matthias M   Metzler Gisela G   Eigentler Thomas T   Münch Anne-Kristin AK   Forchhammer Stephan S  

Diagnostics (Basel, Switzerland) 20221202 12


<h4>Background</h4>Digitally stained ex vivo confocal laser scanning microscopy (CLSM) scans are a possible alternative to formalin-fixed and paraffin-embedded (FFPE) and hematoxylin-eosin (H&E) stained slides. This study explores the diagnostic accuracy of digitally-stained CLSM scans in comparison to H&E-stained slides in various dermatologic diseases in a real-life setting.<h4>Methods</h4>Samples of patients out of one selected dermatologic office were primarily scanned via CLSM; a diagnosis  ...[more]

Similar Datasets

| S-EPMC2587633 | biostudies-literature
| S-EPMC6512973 | biostudies-literature
| S-EPMC10457288 | biostudies-literature
| S-EPMC3945399 | biostudies-literature
| S-EPMC4200345 | biostudies-literature
| S-EPMC3817562 | biostudies-literature
| S-EPMC2566306 | biostudies-literature
| S-EPMC4805657 | biostudies-literature
| S-EPMC6327452 | biostudies-literature
| S-EPMC5945773 | biostudies-literature