The Associations of Mean Glucose and Time in Range from Continuous Glucose Monitoring with HbA1c in Adults with Type 2 Diabetes.


ABSTRACT: Associations of mean glucose and time in range (70-180 mg/dL) from continuous glucose monitoring (CGM) with HbA1c in adults with type 2 diabetes are not well characterized. We conducted a secondary analysis of 186 participants from the Hyperglycemic Profiles in Obstructive Sleep Apnea (HYPNOS) trial. Participants simultaneously wore Dexcom G4 and Abbott Libre Pro CGM sensors up to 4 weeks. Mean HbA1c was 7.7% (SD, 1.3). There were strong negative Pearson's correlations of HbA1c with CGM time in range (-0.79, Abbott; -0.81, Dexcom) and strong positive correlations with CGM mean glucose (Dexcom, 0.84; Abbott, 0.82). However, there were large differences in CGM mean glucose (±20 mg/dL) and time in range (±14%) at any given HbA1c value. Mean glucose and HbA1c are strongly correlated in type 2 diabetes patients not taking insulin but discordance is evident at the individual level. Clinicians should expect discordance and use HbA1c and CGM in a complementary manner. ClinicalTrials.gov Identifier: NCT02454153.

SUBMITTER: Selvin E 

PROVIDER: S-EPMC9810347 | biostudies-literature | 2023 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

The Associations of Mean Glucose and Time in Range from Continuous Glucose Monitoring with HbA1c in Adults with Type 2 Diabetes.

Selvin Elizabeth E   Wang Dan D   Rooney Mary R MR   Echouffo-Tcheugui Justin J   Fang Michael M   Zeger Scott S   Sartini Joseph J   Tang Olive O   Coresh Josef J   Aurora R Nisha RN   Punjabi Naresh M NM  

Diabetes technology & therapeutics 20221123 1


Associations of mean glucose and time in range (70-180 mg/dL) from continuous glucose monitoring (CGM) with HbA1c in adults with type 2 diabetes are not well characterized. We conducted a secondary analysis of 186 participants from the Hyperglycemic Profiles in Obstructive Sleep Apnea (HYPNOS) trial. Participants simultaneously wore Dexcom G4 and Abbott Libre Pro CGM sensors up to 4 weeks. Mean HbA1c was 7.7% (SD, 1.3). There were strong negative Pearson's correlations of HbA1c with CGM time in  ...[more]

Similar Datasets

| S-EPMC11885071 | biostudies-literature
| S-EPMC8831812 | biostudies-literature
| S-EPMC8573793 | biostudies-literature
| S-EPMC9641764 | biostudies-literature
| S-EPMC10155499 | biostudies-literature
| S-EPMC7906860 | biostudies-literature
| S-EPMC9631528 | biostudies-literature
| S-EPMC5444486 | biostudies-other
| S-EPMC11688699 | biostudies-literature
| S-EPMC7698997 | biostudies-literature