Unknown

Dataset Information

0

Can composite packaging and selective enamel etching affect the clinical behavior of bulk-fill composite resin in posterior restorations? 24-month results of a randomized clinical trial.


ABSTRACT:

Objectives

This is a double-blind, split-mouth, randomized clinical study that aims to evaluate the influence of bulk-fill composite packaging presented in syringes (BSy) and capsules (BCa), and the effect of selective enamel etching (SEE) on the clinical performance of class I and II bulk-fill resin composite restorations after 24 months.

Methodology

A total of 295 class I or class II restorations were performed on 70 patients. One universal adhesive was applied in all restorations. SEE was used in 148 restorations and self-etching mode (SET) in 147 restorations. After the adhesive application, cavities were restored with Filtek Bulk-fill Posterior Restorative in syringes (BSy), Filtek One Bulk-fill in capsules (BCa), or Filtek Supreme Ultra in syringes with the incremental technique (In). All restorations were evaluated using the FDI criteria after one week and after six, 12, and 24 months. Kaplan-Meier survival analysis and Pearson's Chi-square test were used (α=0.05) for statistical analysis.

Results

After 24 months, 62 patients were evaluated and four restorations were lost due to fracture (one for SEEBSy, two for SEEIn, and one for SETIn). No significant differences in the fracture and retention rate were found between groups (p>0.05). SEE showed significantly fewer marginal adaptation defects than SET (p<0.05). BCa and BSy groups showed fewer marginal discrepancies compared to In (p<0.05). Restorations performed with BCa showed less color mismatch than BSy or In (p<0.05).

Conclusion

Although all restorations exhibited satisfactory clinical performance after 24 months of clinical service, the clinical behavior of class I and II restorations' improved when performed with a bulk-fill composite in capsules, mainly when associated with a universal adhesive applied with SEE.

SUBMITTER: Barceleiro MO 

PROVIDER: S-EPMC9972856 | biostudies-literature | 2023

REPOSITORIES: biostudies-literature

altmetric image

Publications

Can composite packaging and selective enamel etching affect the clinical behavior of bulk-fill composite resin in posterior restorations? 24-month results of a randomized clinical trial.

Barceleiro Marcos de Oliveira MO   Tardem Chane C   Albuquerque Elisa Gomes EG   Lopes Leticia de Souza LS   Marins Stella Soares SS   Poubel Luiz Augusto LA   Barcelos Roberta R   Ñaupari-Villasante Romina R   Loguercio Alessandro Dourado AD   Calazans Fernanda Signorelli FS  

Journal of applied oral science : revista FOB 20230213


<h4>Objectives</h4>This is a double-blind, split-mouth, randomized clinical study that aims to evaluate the influence of bulk-fill composite packaging presented in syringes (BSy) and capsules (BCa), and the effect of selective enamel etching (SEE) on the clinical performance of class I and II bulk-fill resin composite restorations after 24 months.<h4>Methodology</h4>A total of 295 class I or class II restorations were performed on 70 patients. One universal adhesive was applied in all restoratio  ...[more]

Similar Datasets

| S-EPMC7464794 | biostudies-literature
| S-EPMC6765082 | biostudies-literature
| S-EPMC5842874 | biostudies-literature
| S-EPMC10847201 | biostudies-literature
| S-EPMC10927878 | biostudies-literature
| S-EPMC9635496 | biostudies-literature
| S-EPMC11439374 | biostudies-literature
| S-EPMC10114595 | biostudies-literature
| S-EPMC10150621 | biostudies-literature
| S-EPMC4970260 | biostudies-literature