Unknown

Dataset Information

0

An efficient transition metal chalcogenide sensor for monitoring respiratory alkalosis.


ABSTRACT: For many biomedical applications, high-precision CO2 detection with a rapid response is essential. Due to the superior surface-active characteristics, 2D materials are particularly crucial for electrochemical sensors. The liquid phase exfoliation method of 2D Co2Te3 production is used to achieve the electrochemical sensing of CO2. The Co2Te3 electrode performs better than other CO2 detectors in terms of linearity, low detection limit, and high sensitivity. The outstanding physical characteristics of the electrocatalyst, including its large specific surface area, quick electron transport, and presence of a surface charge, can be credited for its extraordinary electrocatalytic activity. More importantly, the suggested electrochemical sensor has great repeatability, strong stability, and outstanding selectivity. Additionally, the electrochemical sensor based on Co2Te3 could be used to monitor respiratory alkalosis.

Supplementary information

The online version contains supplementary material available at 10.1007/s13205-023-03497-z.

SUBMITTER: Kumbhakar P 

PROVIDER: S-EPMC9978044 | biostudies-literature | 2023 Mar

REPOSITORIES: biostudies-literature

altmetric image

Publications

An efficient transition metal chalcogenide sensor for monitoring respiratory alkalosis.

Kumbhakar Partha P   Sha Mizaj Shabil MS   Tiwary Chandra Sekhar CS   Muthalif Asan G A AGA   Al-Maadeed Somaya S   Sadasivuni Kishor Kumar KK  

3 Biotech 20230301 3


For many biomedical applications, high-precision CO<sub>2</sub> detection with a rapid response is essential. Due to the superior surface-active characteristics, 2D materials are particularly crucial for electrochemical sensors. The liquid phase exfoliation method of 2D Co<sub>2</sub>Te<sub>3</sub> production is used to achieve the electrochemical sensing of CO<sub>2</sub>. The Co<sub>2</sub>Te<sub>3</sub> electrode performs better than other CO<sub>2</sub> detectors in terms of linearity, low d  ...[more]

Similar Datasets

| S-EPMC4595767 | biostudies-other
| S-EPMC9503997 | biostudies-literature
| S-EPMC7568557 | biostudies-literature
| S-EPMC8924768 | biostudies-literature
| S-EPMC7304865 | biostudies-literature
| S-EPMC8545027 | biostudies-literature
| S-EPMC8860449 | biostudies-literature
| S-EPMC7874248 | biostudies-literature
| S-EPMC1698875 | biostudies-literature
| S-EPMC7075147 | biostudies-literature