Unknown

Dataset Information

0

Point of Care Ultrasound First: An Opportunity to Improve Efficiency for Uncomplicated Pregnancy in the Emergency Department.


ABSTRACT: Introduction: Research suggests emergency providers using point-of-care ultrasound (POCUS) to confirm an uncomplicated intrauterine pregnancy (IUP) can decrease emergency department (ED) length of stay (LOS) compared to a radiology department ultrasound (RADUS). The objective of this study was to compare the time to diagnosis and LOS between POCUS and RADUS patients. Methods: This was a retrospective study at one urban medical center. A standardized tool was used to abstract data from a random sample of pregnant patients diagnosed with uncomplicated IUP between January 2016 and December 2017 at a single tertiary care medical center. Microsoft Excel 2010 software was used to measure time intervals, prepare descriptive statistics, and perform Mann-Whitney U tests to compare differences. Results: A random sample of 836 (36%) of the 2,346 emergency department patients diagnosed with an IUP between 8-20 weeks' gestation during the study period was evaluated for inclusion. Three hundred sixty-six met inclusion criteria and were included in the final analysis. Patients were divided into 2 groups based on which type of ultrasound scan they received first: POCUS (n=165) and RADUS (n=201). Patients who received POCUS were found to have an IUP identified in an average of 48 minutes (95% CI, 43 to 53), while the RADUS group's mean time to diagnosis was 120 minutes (95% CI 113 to 127) with a difference of 72 minutes (95% CI, 63 to 80; p<0.001). The mean LOS for patients who received POCUS was 132 minutes (95% CI, 122 to 142), while that of the RADUS group was 177 minutes (95% CI 170 to 184) with a difference of 45 minutes (95% CI 32 to 56; p<0.001). The study is limited by its single-center, retrospective design and by lack of blinding of data abstractors. Conclusion: Pregnant emergency department patients diagnosed with an uncomplicated IUP between 8-weeks and 20-weeks' gestation had statistically significant reduction in time to diagnosis and disposition from the ED if assessed with POCUS as compared to RADUS.

SUBMITTER: Urquhart S 

PROVIDER: S-EPMC9979936 | biostudies-literature | 2021

REPOSITORIES: biostudies-literature

altmetric image

Publications

Point of Care Ultrasound First: An Opportunity to Improve Efficiency for Uncomplicated Pregnancy in the Emergency Department.

Urquhart Sara S   Stevens Kendall K   Barnes Mariah M   Flannigan Matthew M  

POCUS journal 20210422 1


<b>Introduction:</b> Research suggests emergency providers using point-of-care ultrasound (POCUS) to confirm an uncomplicated intrauterine pregnancy (IUP) can decrease emergency department (ED) length of stay (LOS) compared to a radiology department ultrasound (RADUS). The objective of this study was to compare the time to diagnosis and LOS between POCUS and RADUS patients. <b>Methods:</b> This was a retrospective study at one urban medical center. A standardized tool was used to abstract data f  ...[more]

Similar Datasets

| S-EPMC7220009 | biostudies-literature
| S-EPMC5965109 | biostudies-literature
| S-EPMC8578047 | biostudies-literature
| S-EPMC10247175 | biostudies-literature
| S-EPMC6861055 | biostudies-literature
| S-EPMC7375490 | biostudies-literature
| S-EPMC9197738 | biostudies-literature
| S-EPMC6682226 | biostudies-literature
| S-EPMC8885229 | biostudies-literature
| S-EPMC7854775 | biostudies-literature