Measurement of cardiac function using pressure-volume conductance catheter technique in mice and rats.


ABSTRACT: Ventricular pressure-volume relationships have become well established as the most rigorous and comprehensive ways to assess intact heart function. Thanks to advances in miniature sensor technology, this approach has been successfully translated to small rodents, allowing for detailed characterization of cardiovascular function in genetically engineered mice, testing effects of pharmacotherapies and studying disease conditions. This method is unique for providing measures of left ventricular (LV) performance that are more specific to the heart and less affected by vascular loading conditions. Here we present descriptions and movies for procedures employing this method (anesthesia, intubation and surgical techniques, calibrations). We also provide examples of hemodynamics measurements obtained from normal mice/rats, and from animals with cardiac hypertrophy/heart failure, and describe values for various useful load-dependent and load-independent indexes of LV function obtained using different types of anesthesia. The completion of the protocol takes 1-4 h (depending on the experimental design/end points).

SUBMITTER: Pacher P 

PROVIDER: S-EPMC2597499 | biostudies-other | 2008

REPOSITORIES: biostudies-other

altmetric image

Publications

Measurement of cardiac function using pressure-volume conductance catheter technique in mice and rats.

Pacher Pál P   Nagayama Takahiro T   Mukhopadhyay Partha P   Bátkai Sándor S   Kass David A DA  

Nature protocols 20080101 9


Ventricular pressure-volume relationships have become well established as the most rigorous and comprehensive ways to assess intact heart function. Thanks to advances in miniature sensor technology, this approach has been successfully translated to small rodents, allowing for detailed characterization of cardiovascular function in genetically engineered mice, testing effects of pharmacotherapies and studying disease conditions. This method is unique for providing measures of left ventricular (LV  ...[more]

Similar Datasets

| S-EPMC4422373 | biostudies-literature
| S-EPMC8678755 | biostudies-literature
| S-EPMC8495136 | biostudies-literature
| S-EPMC4241179 | biostudies-literature
| S-EPMC8266787 | biostudies-literature
| S-EPMC7082652 | biostudies-literature
| S-EPMC8445653 | biostudies-literature
| S-EPMC6499229 | biostudies-literature
| S-EPMC3818902 | biostudies-literature
| S-EPMC5523757 | biostudies-literature