Cardiac tamponade and successful pericardiocentesis in an extremely low birth weight neonate with percutaneously inserted central venous line: a case report.


ABSTRACT: BACKGROUND: Pericardial effusion and cardiac tamponade are rare but life-threatening complications of percutaneosuly inserted central line (PICL) use in extremely low birth weight (ELBW) neonates, with an incidence reported between 0.07% and 2% of PICLs placement. Timely diagnosis and pericardiocentesis has been proven to be life-saving. CASE PRESENTATION: The patient was a 620 g birth weight neonate who presented with sudden cardiac instability 18 days after the insertion of a PICL and in spite of a presumed satisfactory position of the catheter tip. The transthoracic echocardiography demonstrated severe pericardial effusion with evidence of cardiac tamponade. Successful urgent subxiphoid pericardiocentesis was performed; totally 2 ml of whitish fluid was collected, which resulted consistent to the composition of the hyperosmolar TPN solution infused. CONCLUSION: Cardiac tamponade should be considered in any newborn with a peripherally inserted central catheter who presents with cardiorespiratory instability (bradycardia, cyanosis and metabolic acidosis), even when lines are believed to be placed correctly.

SUBMITTER: Pizzuti A 

PROVIDER: S-EPMC2821304 | biostudies-other | 2010

REPOSITORIES: biostudies-other

altmetric image

Publications

Cardiac tamponade and successful pericardiocentesis in an extremely low birth weight neonate with percutaneously inserted central venous line: a case report.

Pizzuti Alfredo A   Parodi Emilia E   Abbondi Paola P   Frigerio Mario M  

Cases journal 20100111


<h4>Background</h4>Pericardial effusion and cardiac tamponade are rare but life-threatening complications of percutaneosuly inserted central line (PICL) use in extremely low birth weight (ELBW) neonates, with an incidence reported between 0.07% and 2% of PICLs placement. Timely diagnosis and pericardiocentesis has been proven to be life-saving.<h4>Case presentation</h4>The patient was a 620 g birth weight neonate who presented with sudden cardiac instability 18 days after the insertion of a PICL  ...[more]

Similar Datasets

| S-EPMC9505230 | biostudies-literature
| PRJEB17754 | ENA
| S-EPMC10031215 | biostudies-literature
| S-EPMC6501807 | biostudies-literature
| S-EPMC3647026 | biostudies-literature
| S-EPMC5010186 | biostudies-literature
| S-EPMC9335958 | biostudies-literature
| S-EPMC7447660 | biostudies-literature
| S-EPMC7307762 | biostudies-literature
| S-EPMC8041643 | biostudies-literature