Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: II. An experimental validation.


ABSTRACT: Previously, the authors developed a dual-energy (DE) acquisition technique for a photon-counting digital breast tomosynthesis (DBT) imaging system. Low-energy (LE) and high-energy (HE) images are acquired in a single scan by covering alternate slits of a multislit prepatient collimator with Sn and Cu, respectively. A theoretical model was used to optimize the technique. In this article, an experimental validation of this technique is presented.Experiments were performed on a prototype DBT system. LE and HE projection images were acquired sequentially; either a Sn or a Cu filter was positioned in the filter holder at the exit window of the x-ray tube. Sn filters from 0.113 to 0.242 mm thick and Cu filters from 0.103 to 0.267 mm were used. The images were acquired with a W target at 49 kV. Tomographic images, hereafter referred to as DBT images, were reconstructed using a shift-and-add algorithm. DE-DBT images were obtained by weighted logarithmic subtraction of the LE and HE images. Weighting factors w(t) that optimally cancel breast tissues with two different glandularities were assessed for 20-80 mm thick phantoms with 0%, 50%, and 100% glandularity. The mean and standard deviation in the per-pixel signal intensity (SI) were calculated in the DBT images. These data were used to calculate signal-difference-to-noise ratios (SDNRs) between iodine enhanced and nonenhanced polymethyl methacrylate backgrounds. To illustrate the feasibility of the technique, DE-DBT images of a structured phantom containing iodine disks were assessed. The experimental results were compared against the values obtained from a theoretical model of the imaging system.The average difference between theoretical and experimental w(t) was found to range from 8% to 21%. Experimental w(t) values increase with phantom thickness and Cu thickness, depend somewhat on Sn thickness, and vary more as a function of breast composition in thick breasts than in thin breasts. Theoretical and experimental mean and standard deviation in the per-pixel SI differ by -7% to 10% and by -3% to 4%. Theoretical and experimental SDNR values differ, on average, by 1.5%. Iodine concentrations can be predicted from SDNR; the relationship can be accurately fit to a quadratic. In the images of the structured phantom, iodine concentrations of 1 mg/cm2 and larger are discernable.The strong agreement between experimental and theoretical results in this article indicates that the authors' computer model is accurate.

SUBMITTER: Carton AK 

PROVIDER: S-EPMC3188981 | biostudies-other | 2010 Nov

REPOSITORIES: biostudies-other

Similar Datasets

| S-EPMC3188980 | biostudies-other
| S-EPMC7946949 | biostudies-literature
| S-EPMC5500581 | biostudies-literature
| S-EPMC5207128 | biostudies-literature
| S-EPMC3598765 | biostudies-other
| S-EPMC6092324 | biostudies-literature
| S-EPMC7774945 | biostudies-literature
| S-EPMC4630089 | biostudies-literature
| S-EPMC3745502 | biostudies-other
| S-EPMC7810731 | biostudies-literature