Accurate peptide fragment mass analysis: multiplexed peptide identification and quantification.


ABSTRACT: Fourier transform-all reaction monitoring (FT-ARM) is a novel approach for the identification and quantification of peptides that relies upon the selectivity of high mass accuracy data and the specificity of peptide fragmentation patterns. An FT-ARM experiment involves continuous, data-independent, high mass accuracy MS/MS acquisition spanning a defined m/z range. Custom software was developed to search peptides against the multiplexed fragmentation spectra by comparing theoretical or empirical fragment ions against every fragmentation spectrum across the entire acquisition. A dot product score is calculated against each spectrum to generate a score chromatogram used for both identification and quantification. Chromatographic elution profile characteristics are not used to cluster precursor peptide signals to their respective fragment ions. FT-ARM identifications are demonstrated to be complementary to conventional data-dependent shotgun analysis, especially in cases where the data-dependent method fails because of fragmenting multiple overlapping precursors. The sensitivity, robustness, and specificity of FT-ARM quantification are shown to be analogous to selected reaction monitoring-based peptide quantification with the added benefit of minimal assay development. Thus, FT-ARM is demonstrated to be a novel and complementary data acquisition, identification, and quantification method for the large scale analysis of peptides.

SUBMITTER: Weisbrod CR 

PROVIDER: S-EPMC3319072 | biostudies-other | 2012 Mar

REPOSITORIES: biostudies-other

altmetric image

Publications

Accurate peptide fragment mass analysis: multiplexed peptide identification and quantification.

Weisbrod Chad R CR   Eng Jimmy K JK   Hoopmann Michael R MR   Baker Tahmina T   Bruce James E JE  

Journal of proteome research 20120221 3


Fourier transform-all reaction monitoring (FT-ARM) is a novel approach for the identification and quantification of peptides that relies upon the selectivity of high mass accuracy data and the specificity of peptide fragmentation patterns. An FT-ARM experiment involves continuous, data-independent, high mass accuracy MS/MS acquisition spanning a defined m/z range. Custom software was developed to search peptides against the multiplexed fragmentation spectra by comparing theoretical or empirical  ...[more]

Similar Datasets

| S-EPMC3737598 | biostudies-literature
| S-EPMC2525619 | biostudies-literature
| S-EPMC3568235 | biostudies-literature
| S-EPMC3612390 | biostudies-literature
| S-EPMC3205195 | biostudies-literature
| S-EPMC7057324 | biostudies-literature
| S-EPMC3418804 | biostudies-literature
| S-EPMC6101081 | biostudies-literature
| S-EPMC3317402 | biostudies-literature
| S-EPMC3212438 | biostudies-literature