Unknown

Dataset Information

0

Dispersion-cancelled biological imaging with quantum-inspired interferometry.


ABSTRACT: Quantum information science promises transformative impact over a range of key technologies in computing, communication, and sensing. A prominent example uses entangled photons to overcome the resolution-degrading effects of dispersion in the medical-imaging technology, optical coherence tomography. The quantum solution introduces new challenges: inherently low signal and artifacts, additional unwanted signal features. It has recently been shown that entanglement is not a requirement for automatic dispersion cancellation. Such classical techniques could solve the low-signal problem, however they all still suffer from artifacts. Here, we introduce a method of chirped-pulse interferometry based on shaped laser pulses, and use it to produce artifact-free, high-resolution, dispersion-cancelled images of the internal structure of a biological sample. Our work fulfills one of the promises of quantum technologies: automatic-dispersion-cancellation interferometry in biomedical imaging. It also shows how subtle differences between a quantum technique and its classical analogue may have unforeseen, yet beneficial, consequences.

SUBMITTER: Mazurek MD 

PROVIDER: S-EPMC3613801 | biostudies-other | 2013

REPOSITORIES: biostudies-other

altmetric image

Publications

Dispersion-cancelled biological imaging with quantum-inspired interferometry.

Mazurek M D MD   Schreiter K M KM   Prevedel R R   Kaltenbaek R R   Resch K J KJ  

Scientific reports 20130101


Quantum information science promises transformative impact over a range of key technologies in computing, communication, and sensing. A prominent example uses entangled photons to overcome the resolution-degrading effects of dispersion in the medical-imaging technology, optical coherence tomography. The quantum solution introduces new challenges: inherently low signal and artifacts, additional unwanted signal features. It has recently been shown that entanglement is not a requirement for automat  ...[more]

Similar Datasets

| S-EPMC6804567 | biostudies-literature
| S-EPMC3504357 | biostudies-literature
| S-EPMC5052014 | biostudies-literature
| S-EPMC6060044 | biostudies-literature
| S-EPMC8201641 | biostudies-literature
| S-EPMC8348858 | biostudies-literature
| S-EPMC7347853 | biostudies-literature
| S-EPMC4855535 | biostudies-other
| S-EPMC6642182 | biostudies-literature
| S-EPMC2862004 | biostudies-literature