Comparison of the Johnson-Ettinger vapor intrusion screening model predictions with full three-dimensional model results.


ABSTRACT: The Johnson-Ettinger vapor intrusion model (J-E model) is the most widely used screening tool for evaluating vapor intrusion potential because of its simplicity and convenience of use. Since its introduction about twenty years ago, the J-E model has become a cornerstone in guidance related to the potential for significant vapor intrusion-related exposures. A few papers have been published that claim it is a conservative predictor of exposure, but there has not been a systematic comparison in the open literature of the J-E model predictions with the results of more complete full three-dimensional descriptions of the phenomenon. In this paper, predictions from a three-dimensional model of vapor intrusion, based upon finite element calculations of homogeneous soil scenarios, are directly compared with the results of the J-E model. These results suggest that there are conditions under which the J-E model predictions might be quite reasonable but that there are also others in which the predictions are low as well as high. Some small modifications to the J-E model are also suggested that can bring its predictions into excellent agreement with those of the much more elaborate 3-D models, in some specific cases of homogeneous soils. Finally, both models were compared with actual field data.

SUBMITTER: Yao Y 

PROVIDER: S-EPMC3664551 | biostudies-other | 2011 Mar

REPOSITORIES: biostudies-other

altmetric image

Publications

Comparison of the Johnson-Ettinger vapor intrusion screening model predictions with full three-dimensional model results.

Yao Yijun Y   Shen Rui R   Pennell Kelly G KG   Suuberg Eric M EM  

Environmental science & technology 20110223 6


The Johnson-Ettinger vapor intrusion model (J-E model) is the most widely used screening tool for evaluating vapor intrusion potential because of its simplicity and convenience of use. Since its introduction about twenty years ago, the J-E model has become a cornerstone in guidance related to the potential for significant vapor intrusion-related exposures. A few papers have been published that claim it is a conservative predictor of exposure, but there has not been a systematic comparison in the  ...[more]

Similar Datasets

| S-EPMC5654581 | biostudies-literature
| S-EPMC5755378 | biostudies-literature
| S-EPMC7784703 | biostudies-literature
| S-EPMC5773601 | biostudies-literature
| S-EPMC10031644 | biostudies-literature
| S-EPMC4942491 | biostudies-literature
| S-EPMC5191004 | biostudies-literature
| S-EPMC6084445 | biostudies-other
2018-08-25 | GSE119035 | GEO
2018-05-15 | GSE114378 | GEO