A new optical leaf-clip meter for simultaneous non-destructive assessment of leaf chlorophyll and epidermal flavonoids.


ABSTRACT: We have characterized a new commercial chlorophyll (Chl) and flavonoid (Flav) meter called Dualex 4 Scientific (Dx4). We compared this device to two other Chl meters, the SPAD-502 and the CCM-200. In addition, Dx4 was compared to the leaf-clip Dualex 3 that measures only epidermal Flav. Dx4 is factory-calibrated to provide a linear response to increasing leaf Chl content in units of µg cm(-2), as opposed to both SPAD-502 and CCM-200 that have a non-linear response to leaf Chl content. Our comparative calibration by Chl extraction confirmed these responses. It seems that the linear response of Dx4 derives from the use of 710 nm as the sampling wavelength for transmittance. The major advantage of Dx4 is its simultaneous assessment of Chl and Flav on the same leaf spot. This allows the generation of the nitrogen balance index (NBI) used for crop surveys and nitrogen nutrition management. The Dx4 leaf clip, that incorporates a GPS receiver, can be useful for non-destructive estimation of leaf Chl and Flav contents for ecophysiological research and ground truthing of remote sensing of vegetation. In this work, we also propose a consensus equation for the transformation of SPAD units into leaf Chl content, for general use.

SUBMITTER: Cerovic ZG 

PROVIDER: S-EPMC3666089 | biostudies-other | 2012 Nov

REPOSITORIES: biostudies-other

altmetric image

Publications

A new optical leaf-clip meter for simultaneous non-destructive assessment of leaf chlorophyll and epidermal flavonoids.

Cerovic Zoran G ZG   Masdoumier Guillaume G   Ghozlen Naïma Ben NB   Latouche Gwendal G  

Physiologia plantarum 20120606 3


We have characterized a new commercial chlorophyll (Chl) and flavonoid (Flav) meter called Dualex 4 Scientific (Dx4). We compared this device to two other Chl meters, the SPAD-502 and the CCM-200. In addition, Dx4 was compared to the leaf-clip Dualex 3 that measures only epidermal Flav. Dx4 is factory-calibrated to provide a linear response to increasing leaf Chl content in units of µg cm(-2), as opposed to both SPAD-502 and CCM-200 that have a non-linear response to leaf Chl content. Our compar  ...[more]

Similar Datasets

| S-EPMC10724420 | biostudies-literature
| S-EPMC7154821 | biostudies-literature
| S-EPMC5780453 | biostudies-literature
| S-EPMC6541254 | biostudies-literature
| S-EPMC5325157 | biostudies-literature
| S-EPMC7919282 | biostudies-literature
| S-EPMC7014412 | biostudies-literature
| S-EPMC11314797 | biostudies-literature
| S-EPMC5526878 | biostudies-literature
| S-EPMC5814544 | biostudies-literature