Novel kissing catheter technique for foreign body retrieval.


ABSTRACT: We report a novel technique 'the kissing catheter technique' for retrieval of a broken catheter fragment in a patient undergoing closure of a patent ductus arteriosus.

SUBMITTER: Jaiswal VR 

PROVIDER: S-EPMC4189246 | biostudies-other | 2014 Sep

REPOSITORIES: biostudies-other

altmetric image

Publications

Novel kissing catheter technique for foreign body retrieval.

Jaiswal Vinay R VR   Lanjewar Charan P CP   Phadke Milind S MS   Kerkar Prafulla G PG  

Annals of pediatric cardiology 20140901 3


We report a novel technique 'the kissing catheter technique' for retrieval of a broken catheter fragment in a patient undergoing closure of a patent ductus arteriosus. ...[more]