Quantitative oxygen extraction fraction from 7-Tesla MRI phase: reproducibility and application in multiple sclerosis.


ABSTRACT: Quantitative oxygen extraction fraction (OEF) in cortical veins was studied in patients with multiple sclerosis (MS) and healthy subjects via magnetic resonance imaging (MRI) phase images at 7 Tesla (7 T). Flow-compensated, three-dimensional gradient-echo scans were acquired for absolute OEF quantification in 23 patients with MS and 14 age-matched controls. In patients, we collected T2*-weighted images for characterization of white matter, deep gray matter, and cortical lesions, and also assessed cognitive function. Variability of OEF across readers and scan sessions was evaluated in a subset of volunteers. OEF was averaged from 2 to 3 pial veins in the sensorimotor, parietal, and prefrontal cortical regions for each subject (total of ~10 vessels). We observed good reproducibility of mean OEF, with intraobserver coefficient of variation (COV)=2.1%, interobserver COV=5.2%, and scan-rescan COV=5.9%. Patients exhibited a 3.4% reduction in cortical OEF relative to controls (P=0.0025), which was not different across brain regions. Although oxygenation did not relate with measures of structural tissue damage, mean OEF correlated with a global measure of information processing speed. These findings suggest that cortical OEF from 7-T MRI phase is a reproducible metabolic biomarker that may be sensitive to different pathologic processes than structural MRI in patients with MS.

SUBMITTER: Fan AP 

PROVIDER: S-EPMC4294406 | biostudies-other | 2015 Jan

REPOSITORIES: biostudies-other

altmetric image

Publications

Quantitative oxygen extraction fraction from 7-Tesla MRI phase: reproducibility and application in multiple sclerosis.

Fan Audrey P AP   Govindarajan Sindhuja T ST   Kinkel R Philip RP   Madigan Nancy K NK   Nielsen A Scott AS   Benner Thomas T   Tinelli Emanuele E   Rosen Bruce R BR   Adalsteinsson Elfar E   Mainero Caterina C  

Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism 20141029 1


Quantitative oxygen extraction fraction (OEF) in cortical veins was studied in patients with multiple sclerosis (MS) and healthy subjects via magnetic resonance imaging (MRI) phase images at 7 Tesla (7 T). Flow-compensated, three-dimensional gradient-echo scans were acquired for absolute OEF quantification in 23 patients with MS and 14 age-matched controls. In patients, we collected T2*-weighted images for characterization of white matter, deep gray matter, and cortical lesions, and also assesse  ...[more]

Similar Datasets

| S-EPMC7730517 | biostudies-literature
| S-EPMC6772021 | biostudies-literature
| S-EPMC8415351 | biostudies-literature
| S-EPMC6093849 | biostudies-other
| S-EPMC7187719 | biostudies-literature
| S-EPMC7026852 | biostudies-literature
| S-EPMC7168796 | biostudies-literature
| S-EPMC4945460 | biostudies-literature
| S-EPMC5607538 | biostudies-literature
| S-EPMC7540168 | biostudies-literature