Unknown

Dataset Information

0

Influence of temporal regularization and radial undersampling factor on compressed sensing reconstruction in dynamic contrast enhanced MRI of the breast.


ABSTRACT: To evaluate the influence of temporal sparsity regularization and radial undersampling on compressed sensing reconstruction of dynamic contrast-enhanced (DCE) MRI, using the iterative Golden-angle RAdial Sparse Parallel (iGRASP) MRI technique in the setting of breast cancer evaluation.DCE-MRI examinations of the breast (n?=?7) were conducted using iGRASP at 3 Tesla. Images were reconstructed with five different radial undersampling schemes corresponding to temporal resolutions between 2 and 13.4 s/frame and with four different weights for temporal sparsity regularization (??=?0.1, 0.5, 2, and 6 times of noise level). Image similarity to time-averaged reference images was assessed by two breast radiologists and using quantitative metrics. Temporal similarity was measured in terms of wash-in slope and contrast kinetic model parameters.iGRASP images reconstructed with ??=?2 and 5.1 s/frame had significantly (P?5%), in agreement with the assessment of two breast radiologists. Higher undersampling (temporal resolution??23% between ??=?2 and 0.5). The difference between the kinetic-model transfer rates of benign and malignant groups decreased as temporal resolution decreased (82% between 2 and 13.4 s/frame).This study demonstrates objective spatial and temporal similarity measures can be used to assess the influence of sparsity constraint and undersampling in compressed sensing DCE-MRI and also shows that the iGRASP method provides the flexibility of optimizing these reconstruction parameters in the postprocessing stage using the same acquired data.

SUBMITTER: Kim SG 

PROVIDER: S-EPMC4666836 | biostudies-other | 2016 Jan

REPOSITORIES: biostudies-other

altmetric image

Publications

Influence of temporal regularization and radial undersampling factor on compressed sensing reconstruction in dynamic contrast enhanced MRI of the breast.

Kim Sungheon G SG   Feng Li L   Grimm Robert R   Freed Melanie M   Block Kai Tobias KT   Sodickson Daniel K DK   Moy Linda L   Otazo Ricardo R  

Journal of magnetic resonance imaging : JMRI 20150601 1


<h4>Background</h4>To evaluate the influence of temporal sparsity regularization and radial undersampling on compressed sensing reconstruction of dynamic contrast-enhanced (DCE) MRI, using the iterative Golden-angle RAdial Sparse Parallel (iGRASP) MRI technique in the setting of breast cancer evaluation.<h4>Methods</h4>DCE-MRI examinations of the breast (n = 7) were conducted using iGRASP at 3 Tesla. Images were reconstructed with five different radial undersampling schemes corresponding to temp  ...[more]

Similar Datasets

| S-EPMC6126447 | biostudies-literature
| S-EPMC4583338 | biostudies-literature
| S-EPMC3991777 | biostudies-literature
| S-EPMC6755916 | biostudies-literature
2012-08-16 | E-GEOD-36562 | biostudies-arrayexpress
| S-EPMC7017458 | biostudies-literature
2012-08-16 | GSE36562 | GEO
| S-EPMC6089682 | biostudies-literature
| S-EPMC2582941 | biostudies-literature
| S-EPMC6258350 | biostudies-literature