Use of thoracic electrical impedance tomography as an auxiliary tool for alveolar recruitment maneuvers in acute respiratory distress syndrome: case report and brief literature review.


ABSTRACT: Thoracic electrical impedance tomography is a real-time, noninvasive monitoring tool of the regional pulmonary ventilation distribution. Its bedside use in patients with acute respiratory distress syndrome has the potential to aid in alveolar recruitment maneuvers, which are often necessary in cases of refractory hypoxemia. In this case report, we describe the monitoring results and interpretation of thoracic electrical impedance tomography used during alveolar recruitment maneuvers in a patient with acute respiratory distress syndrome, with transient application of high alveolar pressures and optimal positive end-expiratory pressure titration. Furthermore, we provide a brief literature review regarding the use of alveolar recruitment maneuvers and monitoring using thoracic electrical impedance tomography in patients with acute respiratory distress syndrome.

SUBMITTER: Rosa RG 

PROVIDER: S-EPMC4738829 | biostudies-other | 2015 Oct-Dec

REPOSITORIES: biostudies-other

altmetric image

Publications

Use of thoracic electrical impedance tomography as an auxiliary tool for alveolar recruitment maneuvers in acute respiratory distress syndrome: case report and brief literature review.

Rosa Regis Goulart RG   Rutzen William W   Madeira Laura L   Ascoli Aline Maria AM   Dexheimer Neto Felippe Leopoldo FL   Maccari Juçara Gasparetto JG   Oliveira Roselaine Pinheiro de RP   Teixeira Cassiano C  

Revista Brasileira de terapia intensiva 20151001 4


Thoracic electrical impedance tomography is a real-time, noninvasive monitoring tool of the regional pulmonary ventilation distribution. Its bedside use in patients with acute respiratory distress syndrome has the potential to aid in alveolar recruitment maneuvers, which are often necessary in cases of refractory hypoxemia. In this case report, we describe the monitoring results and interpretation of thoracic electrical impedance tomography used during alveolar recruitment maneuvers in a patient  ...[more]

Similar Datasets

| S-EPMC5537118 | biostudies-other
| S-EPMC9354895 | biostudies-literature
| S-EPMC10870845 | biostudies-literature
| S-EPMC9435385 | biostudies-literature
| S-EPMC6528207 | biostudies-literature
| S-EPMC6723902 | biostudies-other
| S-EPMC5627850 | biostudies-literature
| S-EPMC8727044 | biostudies-literature
| S-EPMC6406466 | biostudies-literature
| S-EPMC7719729 | biostudies-literature