Unknown

Dataset Information

0

Long-Term Behavior of Simulated Partial Lead Service Line Replacements.


ABSTRACT: In this 48-month pilot study, long-term impacts of copper:lead galvanic connections on lead release to water were assessed without confounding differences in pipe exposure prehistory or disturbances arising from cutting lead pipe. Lead release was tracked from three lead service line configurations, including (1) 100% lead, (2) traditional partial replacement with 50% copper upstream of 50% lead, and (3) 50% lead upstream of 50% copper as a function of flow rate, connection types, and sampling methodologies. Elevated lead from galvanic corrosion worsened with time, with 140% more lead release from configurations representing traditional partial replacement configurations at 14 months compared to earlier data in the first 8 months. Even when sampled consistently at moderate flow rate (8 LPM) and collecting all water passing through service lines, conditions representing traditional partial service line configurations were significantly worse (?40%) when compared to 100% lead pipe. If sampled at a high flow rate (32 LPM) and collecting 2?L samples from service lines, 100% of samples collected from traditional partial replacement configurations exceeded thresholds posing an acute health risk versus a 0% risk for samples from 100% lead pipe. Temporary removal of lead accumulations near Pb:Cu junctions and lead deposits from other downstream plastic pipes reduced risk of partial replacements relative to that observed for 100% lead. When typical brass compression couplings were used to connect prepassivated lead pipes, lead release spiked up to 10 times higher, confirming prior concerns raised at bench and field scale regarding adverse impacts of crevices and service line disturbances on lead release. To quantify semirandom particulate lead release from service lines in future research, whole-house filters have many advantages compared to other approaches.

SUBMITTER: St Clair J 

PROVIDER: S-EPMC4770854 | biostudies-other | 2016 Jan

REPOSITORIES: biostudies-other

altmetric image

Publications

Long-Term Behavior of Simulated Partial Lead Service Line Replacements.

St Clair Justin J   Cartier Clement C   Triantafyllidou Simoni S   Clark Brandi B   Edwards Marc M  

Environmental engineering science 20160101 1


In this 48-month pilot study, long-term impacts of copper:lead galvanic connections on lead release to water were assessed without confounding differences in pipe exposure prehistory or disturbances arising from cutting lead pipe. Lead release was tracked from three lead service line configurations, including (1) 100% lead, (2) traditional partial replacement with 50% copper upstream of 50% lead, and (3) 50% lead upstream of 50% copper as a function of flow rate, connection types, and sampling m  ...[more]

Similar Datasets

| S-EPMC3147460 | biostudies-literature
| S-EPMC2481365 | biostudies-literature
| S-EPMC10080065 | biostudies-literature
| S-EPMC5612372 | biostudies-literature
| S-EPMC6265915 | biostudies-other
| S-EPMC3268284 | biostudies-literature
| S-EPMC6541405 | biostudies-literature
| S-EPMC9194130 | biostudies-literature
| S-EPMC7255958 | biostudies-literature
| S-EPMC8745716 | biostudies-literature