Unknown

Dataset Information

0

Multi-Modal Imaging in a Mouse Model of Orthotopic Lung Cancer.


ABSTRACT: Investigation of CF800, a novel PEGylated nano-liposomal imaging agent containing indocyanine green (ICG) and iohexol, for real-time near infrared (NIR) fluorescence and computed tomography (CT) image-guided surgery in an orthotopic lung cancer model in nude mice.CF800 was intravenously administered into 13 mice bearing the H460 orthotopic human lung cancer. At 48 h post-injection (peak imaging agent accumulation time point), ex vivo NIR and CT imaging was performed. A clinical NIR imaging system (SPY®, Novadaq) was used to measure fluorescence intensity of tumor and lung. Tumor-to-background-ratios (TBR) were calculated in inflated and deflated states. The mean Hounsfield unit (HU) of lung tumor was quantified using the CT data set and a semi-automated threshold-based method. Histological evaluation using H&E, the macrophage marker F4/80 and the endothelial cell marker CD31, was performed, and compared to the liposomal fluorescence signal obtained from adjacent tissue sections.The fluorescence TBR measured when the lung is in the inflated state (2.0 ± 0.58) was significantly greater than in the deflated state (1.42 ± 0.380 (n = 7, p<0.003). Mean fluorescent signal in tumor was highly variable across samples, (49.0 ± 18.8 AU). CT image analysis revealed greater contrast enhancement in lung tumors (a mean increase of 110 ± 57 HU) when CF800 is administered compared to the no contrast enhanced tumors (p = 0.0002).Preliminary data suggests that the high fluorescence TBR and CT tumor contrast enhancement provided by CF800 may have clinical utility in localization of lung cancer during CT and NIR image-guided surgery.

SUBMITTER: Patel P 

PROVIDER: S-EPMC5008802 | biostudies-other | 2016

REPOSITORIES: biostudies-other

altmetric image

Publications


<h4>Background</h4>Investigation of CF800, a novel PEGylated nano-liposomal imaging agent containing indocyanine green (ICG) and iohexol, for real-time near infrared (NIR) fluorescence and computed tomography (CT) image-guided surgery in an orthotopic lung cancer model in nude mice.<h4>Methods</h4>CF800 was intravenously administered into 13 mice bearing the H460 orthotopic human lung cancer. At 48 h post-injection (peak imaging agent accumulation time point), ex vivo NIR and CT imaging was perf  ...[more]

Similar Datasets

| S-EPMC8342546 | biostudies-literature
| S-EPMC10235890 | biostudies-literature
| S-EPMC8141172 | biostudies-literature
| S-EPMC7586303 | biostudies-literature
| S-EPMC4529312 | biostudies-literature
| S-EPMC4880291 | biostudies-literature
| S-EPMC9400884 | biostudies-literature
| S-EPMC5091834 | biostudies-other
| S-EPMC6144215 | biostudies-literature
| S-EPMC5552689 | biostudies-literature