Unknown

Dataset Information

0

A sensitive electrochemical sensor for in vitro detection of parathyroid hormone based on a MoS2-graphene composite.


ABSTRACT: This paper reports a biosensor based on a MoS2-graphene (MG) composite that can measure the parathyroid hormone (PTH) concentration in serum samples from patients. The interaction between PTH and MG was analysed via an electrochemical sensing technique. The MG was functionalized using l-cysteine. Following this, PTH could be covalently immobilized on the MG sensing electrode. The properties of MG were evaluated using scanning electron microscopy, high-resolution transmission electron microscopy, X-ray diffraction, Raman spectroscopy, X-ray photoelectron spectroscopy, and Fourier transform infrared spectrometry. Following optimization of immobilized materials-such as MG, PTH, and alkaline phosphatase (ALP)-the performance of the MG sensor was investigated via cyclic voltammetry, to assess its linearity, repeatability, and reproducibility. Electrochemical impedance spectroscopy was performed on graphene oxide (GO) and MG-modified electrodes to confirm the capture of a monoclonal antibody (MAb) targeting PTH. Furthermore, the ALP-PTH-MG sensor exhibits a linear response towards PTH from artificial serum over a range of 1-50?pg mL(-1). Moreover, patient sera (n?=?30) were evaluated using the ALP-PTH-MG sensor and compared using standard equipment (Roche E 170). The P-value is less than 0.01 when evaluated with a t-test using Welch's correction. This implies that the fabricated sensor can be deployed for medical diagnosis.

SUBMITTER: Kim HU 

PROVIDER: S-EPMC5046135 | biostudies-other | 2016 Oct

REPOSITORIES: biostudies-other

altmetric image

Publications

A sensitive electrochemical sensor for in vitro detection of parathyroid hormone based on a MoS<sub>2</sub>-graphene composite.

Kim Hyeong-U HU   Kim Hye Youn HY   Kulkarni Atul A   Ahn Chisung C   Jin Yinhua Y   Kim Yeongseok Y   Lee Kook-Nyung KN   Lee Min-Ho MH   Kim Taesung T  

Scientific reports 20161003


This paper reports a biosensor based on a MoS<sub>2</sub>-graphene (MG) composite that can measure the parathyroid hormone (PTH) concentration in serum samples from patients. The interaction between PTH and MG was analysed via an electrochemical sensing technique. The MG was functionalized using l-cysteine. Following this, PTH could be covalently immobilized on the MG sensing electrode. The properties of MG were evaluated using scanning electron microscopy, high-resolution transmission electron  ...[more]

Similar Datasets

| S-EPMC9064582 | biostudies-literature
| S-EPMC9837858 | biostudies-literature
| S-EPMC4964632 | biostudies-literature
| S-EPMC8746692 | biostudies-literature
| S-EPMC8981263 | biostudies-literature
| S-EPMC8263621 | biostudies-literature
| S-EPMC9954471 | biostudies-literature
| S-EPMC7085571 | biostudies-literature
| S-EPMC6289492 | biostudies-literature
| S-EPMC8467804 | biostudies-literature