The influence of tip shape on bending force during needle insertion.


ABSTRACT: Steering of needles involves the planning and timely modifying of instrument-tissue force interactions to allow for controlled deflections during the insertion in tissue. In this work, the effect of tip shape on these forces was studied using 10?mm diameter needle tips. Six different tips were selected, including beveled and conical versions, with or without pre-bend or pre-curve. A six-degree-of-freedom force/torque sensor measured the loads during indentations in tissue simulants. The increased insertion (axial) and bending (radial) forces with insertion depth - the force-displacement slopes - were analyzed. Results showed that the ratio between radial and axial forces was not always proportional. This means that the tip load does not have a constant orientation, as is often assumed in mechanics-based steering models. For all tip types, the tip-load assumed a more radial orientation with increased axial load. This effect was larger for straight tips than for pre-bent or pre-curved tips. In addition, the force-displacement slopes were consistently higher for (1) increased tip angles, and for (2) beveled tips compared to conical tips. Needles with a bent or curved tip allow for an increased bending force and a decreased variability of the tip load vector orientation.

SUBMITTER: van de Berg NJ 

PROVIDER: S-EPMC5225462 | biostudies-other | 2017 Jan

REPOSITORIES: biostudies-other

altmetric image

Publications

The influence of tip shape on bending force during needle insertion.

van de Berg Nick J NJ   de Jong Tonke L TL   van Gerwen Dennis J DJ   Dankelman Jenny J   van den Dobbelsteen John J JJ  

Scientific reports 20170111


Steering of needles involves the planning and timely modifying of instrument-tissue force interactions to allow for controlled deflections during the insertion in tissue. In this work, the effect of tip shape on these forces was studied using 10 mm diameter needle tips. Six different tips were selected, including beveled and conical versions, with or without pre-bend or pre-curve. A six-degree-of-freedom force/torque sensor measured the loads during indentations in tissue simulants. The increase  ...[more]

Similar Datasets

| S-EPMC6785597 | biostudies-literature
| S-EPMC8055898 | biostudies-literature
| S-EPMC5098966 | biostudies-literature
| S-EPMC6967171 | biostudies-literature
| S-EPMC6195562 | biostudies-literature
2010-07-01 | E-GEOD-5646 | biostudies-arrayexpress
| S-EPMC1693798 | biostudies-literature
2007-01-01 | GSE5646 | GEO