The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography.


ABSTRACT: OBJECTIVES:To assess the impact of combining low-tube voltage acquisition with iterative reconstruction (IR) techniques on the iodine dose in coronary CTA. METHODS:Three minipigs underwent CCTA to compare a standard of care protocol with two alternative study protocols combining low-tube voltage and low iodine dose with IR. Image quality was evaluated objectively by the CT value, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the main coronary arteries and aorta and subjectively by expert reading. Statistics were performed by Mann-Whitney U test and Chi-square analysis. RESULTS:Despite reduced iodine dose, both study protocols maintained CT values, SNR, and CNR compared to the standard of care protocol. Expert readings confirmed these findings; all scans were perceived to be of at least diagnostically acceptable quality on all evaluated parameters allowing image interpretation. No statistical differences were observed (all p values > 0.11), except for streak artifacts (p = 0.02) which were considered to be more severe, although acceptable, with the 80 kVp protocol. CONCLUSIONS:Reduced tube voltage in combination with IR allows a total iodine dose reduction between 37 and 50%, by using contrast media with low iodine concentrations of 200 and 160 mg I/mL, while maintaining image quality.

SUBMITTER: Van Cauteren T 

PROVIDER: S-EPMC5460391 | biostudies-other | 2017

REPOSITORIES: biostudies-other

altmetric image

Publications

The Impact of Combining a Low-Tube Voltage Acquisition with Iterative Reconstruction on Total Iodine Dose in Coronary CT Angiography.

Van Cauteren Toon T   Van Gompel Gert G   Tanaka Kaoru K   Verdries Douwe E DE   Belsack Dries D   Nieboer Koenraad H KH   Willekens Inneke I   Evans Paul P   Macholl Sven S   Verfaillie Guy G   Droogmans Steven S   de Mey Johan J   Buls Nico N  

BioMed research international 20170523


<h4>Objectives</h4>To assess the impact of combining low-tube voltage acquisition with iterative reconstruction (IR) techniques on the iodine dose in coronary CTA.<h4>Methods</h4>Three minipigs underwent CCTA to compare a standard of care protocol with two alternative study protocols combining low-tube voltage and low iodine dose with IR. Image quality was evaluated objectively by the CT value, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) in the main coronary arteries and aorta  ...[more]

Similar Datasets

| S-EPMC6201985 | biostudies-literature
| S-EPMC9142122 | biostudies-literature
| S-EPMC5017721 | biostudies-literature
| S-EPMC7365455 | biostudies-literature
| S-EPMC7977955 | biostudies-literature
| S-EPMC8631019 | biostudies-literature
| S-EPMC7458859 | biostudies-literature
| S-EPMC3807656 | biostudies-literature
| S-EPMC6362232 | biostudies-other
| S-EPMC5017776 | biostudies-literature