Unknown

Dataset Information

0

A two-pool model to describe the IVIM cerebral perfusion.


ABSTRACT: IntraVoxel Incoherent Motion (IVIM) is a magnetic resonance imaging (MRI) technique capable of measuring perfusion-related parameters. In this manuscript, we show that the mono-exponential model commonly used to process IVIM data might be challenged, especially at short diffusion times. Eleven rat datasets were acquired at 7T using a diffusion-weighted pulsed gradient spin echo sequence with b-values ranging from 7 to 2500?s/mm2 at three diffusion times. The IVIM signals, obtained by removing the diffusion component from the raw MR signal, were fitted to the standard mono-exponential model, a bi-exponential model and the Kennan model. The Akaike information criterion used to find the best model to fit the data demonstrates that, at short diffusion times, the bi-exponential IVIM model is most appropriate. The results obtained by comparing the experimental data to a dictionary of numerical simulations of the IVIM signal in microvascular networks support the hypothesis that such a bi-exponential behavior can be explained by considering the contribution of two vascular pools: capillaries and somewhat larger vessels.

SUBMITTER: Fournet G 

PROVIDER: S-EPMC5536805 | biostudies-other | 2017 Aug

REPOSITORIES: biostudies-other

altmetric image

Publications

A two-pool model to describe the IVIM cerebral perfusion.

Fournet Gabrielle G   Li Jing-Rebecca JR   Cerjanic Alex M AM   Sutton Bradley P BP   Ciobanu Luisa L   Le Bihan Denis D  

Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism 20160101 8


IntraVoxel Incoherent Motion (IVIM) is a magnetic resonance imaging (MRI) technique capable of measuring perfusion-related parameters. In this manuscript, we show that the mono-exponential model commonly used to process IVIM data might be challenged, especially at short diffusion times. Eleven rat datasets were acquired at 7T using a diffusion-weighted pulsed gradient spin echo sequence with b-values ranging from 7 to 2500 s/mm<sup>2</sup> at three diffusion times. The IVIM signals, obtained by  ...[more]

Similar Datasets

| S-EPMC9670000 | biostudies-literature
| S-EPMC2997845 | biostudies-literature
| S-EPMC10824768 | biostudies-literature
| S-EPMC10824556 | biostudies-literature
| S-EPMC7870815 | biostudies-literature
| S-EPMC2481444 | biostudies-literature
| S-EPMC6620253 | biostudies-literature
| S-EPMC4150128 | biostudies-literature
| S-EPMC4562004 | biostudies-literature
| S-EPMC8304869 | biostudies-literature