Unknown

Dataset Information

0

Subthreshold 577 nm micropulse laser treatment for central serous chorioretinopathy.


ABSTRACT: To compare the efficacy of the subthreshold micropulse laser (SML) to conventional laser (CL) in treating focal leakages of the retinal pigment epithelium (RPE) in the eyes with central serous chorioretinopathy (CSC).Twenty-nine eyes of 28 patients with CSC and typical focal leakage were treated with CL or SML. Both treatments were made with a 577 nm yellow laser (CL: NIDEK MC-500, SML: IRIDEX IQ577). The percentage of eyes with a complete resolution, the distance of the laser burns from the fovea, and injury of the RPE after treatment were studied.A complete resolution was seen in 10 of 15 eyes (66.7%) after CL and 9 of 14 eyes (64.3%) after SML (P = 0.89). The average distance from the foveal center to the leakage point was 1282±596 ?m for eyes treated with CL and 1271±993 ?m for eyes treated with SML (P = 0.4). Only three eyes treated with SML had treatment sites within 500 ?m of the fovea. RPE damage determined by fundus autofluorescence was found in all eyes treated with CL and only one eye treated with SML (P<.01).SML achieved equivalent therapeutic effects as CL but without RPE damage in eyes with CSC.

SUBMITTER: Maruko I 

PROVIDER: S-EPMC5574536 | biostudies-other | 2017

REPOSITORIES: biostudies-other

altmetric image

Publications

Subthreshold 577 nm micropulse laser treatment for central serous chorioretinopathy.

Maruko Ichiro I   Koizumi Hideki H   Hasegawa Taiji T   Arakawa Hisaya H   Iida Tomohiro T  

PloS one 20170829 8


<h4>Purpose</h4>To compare the efficacy of the subthreshold micropulse laser (SML) to conventional laser (CL) in treating focal leakages of the retinal pigment epithelium (RPE) in the eyes with central serous chorioretinopathy (CSC).<h4>Methods</h4>Twenty-nine eyes of 28 patients with CSC and typical focal leakage were treated with CL or SML. Both treatments were made with a 577 nm yellow laser (CL: NIDEK MC-500, SML: IRIDEX IQ577). The percentage of eyes with a complete resolution, the distance  ...[more]

Similar Datasets

| S-EPMC5129861 | biostudies-literature
| S-EPMC7692124 | biostudies-literature
| S-EPMC8322653 | biostudies-literature
| S-EPMC7608089 | biostudies-literature
| S-EPMC3272193 | biostudies-other
| S-EPMC4625218 | biostudies-literature
| S-EPMC7806452 | biostudies-literature
| S-EPMC7271527 | biostudies-literature
| S-EPMC7448152 | biostudies-literature
| S-EPMC4578347 | biostudies-literature