Accuracy and User Performance Evaluation of a New, Wireless-enabled Blood Glucose Monitoring System That Links to a Smart Mobile Device.


ABSTRACT: The new Contour®Plus ONE blood glucose monitoring system (BGMS) features an easy-to-use, wireless-enabled blood glucose meter that links to a smart mobile device via Bluetooth® connectivity and can sync with the Contour™ Diabetes app on a smartphone or tablet.The accuracy of the new BGMS was assessed in 2 studies according to ISO 15197:2013 criteria. In Study 1 (laboratory study), fingertip capillary blood samples from 100 subjects were tested in duplicate using 3 test strip lots. In Study 2 (clinical study), 134 subjects with type 1 or type 2 diabetes enrolled at 2 clinical sites. BGMS results and YSI analyzer (YSI) reference results were compared for fingertip blood obtained by untrained subjects' self-testing and for study staff-obtained fingertip, subject palm, and venous results.In Study 1, 99.0% (594/600) of combined results for all 3 test strip lots fulfilled ISO 15197:2013 Section 6.3 accuracy criteria. In Study 2, 99.2% (133/134) of subject-obtained capillary fingertip results, 99.2% (133/134) of study staff-obtained fingertip results, 99.2% (125/126) of subject-obtained palm results, and 100% (132/132) of study staff-obtained venous results met ISO 15197:2013 Section 8 accuracy criteria. Moreover, 95.5% (128/134) of subject-obtained fingertip self-test results were within ±10 mg/dl (±0.6 mmol/L) or ±10% of the YSI reference result. Questionnaire results showed that most subjects found the BGMS easy to use.The BGMS exceeded ISO 15197:2013 accuracy criteria both in the laboratory and in a clinical setting when used by untrained subjects with diabetes.

SUBMITTER: Bailey TS 

PROVIDER: S-EPMC5588817 | biostudies-other | 2017 Jul

REPOSITORIES: biostudies-other

altmetric image

Publications

Accuracy and User Performance Evaluation of a New, Wireless-enabled Blood Glucose Monitoring System That Links to a Smart Mobile Device.

Bailey Timothy S TS   Wallace Jane F JF   Pardo Scott S   Warchal-Windham Mary Ellen ME   Harrison Bern B   Morin Robert R   Christiansen Mark M  

Journal of diabetes science and technology 20170201 4


<h4>Background</h4>The new Contour<sup>®</sup>Plus ONE blood glucose monitoring system (BGMS) features an easy-to-use, wireless-enabled blood glucose meter that links to a smart mobile device via Bluetooth<sup>®</sup> connectivity and can sync with the Contour<sup>™</sup> Diabetes app on a smartphone or tablet.<h4>Methods</h4>The accuracy of the new BGMS was assessed in 2 studies according to ISO 15197:2013 criteria. In Study 1 (laboratory study), fingertip capillary blood samples from 100 subje  ...[more]

Similar Datasets

| S-EPMC8748626 | biostudies-literature
| S-EPMC4056592 | biostudies-literature
| S-EPMC5132399 | biostudies-literature
| S-EPMC8080268 | biostudies-literature
| S-EPMC8571685 | biostudies-literature
| S-EPMC7896142 | biostudies-literature
| S-EPMC7490371 | biostudies-literature
| S-EPMC3571774 | biostudies-literature
| S-EPMC4926082 | biostudies-other
| S-EPMC6724359 | biostudies-literature