Label-free Rapid Viable Enrichment of Circulating Tumor Cell by Photosensitive Polymer-based Microfilter Device.


ABSTRACT: We present a clinical device for simple, rapid, and viable isolation of circulating tumor cells (CTCs) from cancer patient bloods. In spite of the clinical importance of CTCs, the lack of easy and non-biased isolation methods is a big hurdle for implementing CTC into clinical use. The present device made of photosensitive polymer was designed to attach to conventional syringe to isolate the CTCs at minimal resources. Its unique tapered-slits on the filter are capable not only to isolate the cell based on their size and deformability, but also to increase sample flow rate, thus achieving label-free rapid viable CTC isolation. We verified our device performance using 9 different types of cancer cells at the cell concentration from 5 to 100cells/ml, showing that the device capture 77.7% of the CTCs while maintaining their viability of 80.6%. We extended our study using the 18 blood samples from lung, colorectal, pancreatic and renal cancer patients and captured 1-172 CTCs or clustered CTCs by immunofluorescent or immunohistochemical staining. The captured CTCs were also molecularly assayed by RT-PCR with three cancer-associated genes (CK19, EpCAM, and MUC1). Those comprehensive studies proved to use our device for cancer study, thereby inaugurating further in-depth CTC-based clinical researches.

SUBMITTER: Kang YT 

PROVIDER: S-EPMC5595125 | biostudies-other | 2017

REPOSITORIES: biostudies-other

altmetric image

Publications

Label-free Rapid Viable Enrichment of Circulating Tumor Cell by Photosensitive Polymer-based Microfilter Device.

Kang Yoon-Tae YT   Doh Il I   Byun Jiyoung J   Chang Hee Jin HJ   Cho Young-Ho YH  

Theranostics 20170722 13


We present a clinical device for simple, rapid, and viable isolation of circulating tumor cells (CTCs) from cancer patient bloods. In spite of the clinical importance of CTCs, the lack of easy and non-biased isolation methods is a big hurdle for implementing CTC into clinical use. The present device made of photosensitive polymer was designed to attach to conventional syringe to isolate the CTCs at minimal resources. Its unique tapered-slits on the filter are capable not only to isolate the cell  ...[more]

Similar Datasets

| S-EPMC4260227 | biostudies-literature
2015-05-17 | E-GEOD-67939 | biostudies-arrayexpress
2015-05-17 | GSE67939 | GEO
2023-09-12 | E-MTAB-13288 | biostudies-arrayexpress
| S-EPMC4490017 | biostudies-literature
| S-EPMC6590080 | biostudies-literature
| S-EPMC5576172 | biostudies-literature
| S-EPMC6187722 | biostudies-literature
| S-EPMC6491348 | biostudies-literature