Unknown

Dataset Information

0

Accuracy of dynamic contrast-enhanced magnetic resonance imaging in the diagnosis of prostate cancer: systematic review and meta-analysis.


ABSTRACT: The goals of this meta-analysis were to assess the effectiveness of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in patients with prostate carcinoma (PCa) and to explore the risk profiles with the highest benefit. Systematic electronic searched were conducted in database. We used patient-based and biopsy-based pooled weighted estimates of the sensitivity, specificity, and a summary receiver operating characteristic (SROC) curve for assessing the diagnostic performance of DCE. We performed direct and indirect comparisons of DCE and other methods of imaging. A total of 26 articles met the inclusion criteria for the analysis. DCE-MRI pooled sensitivity was 0.53 (95% CI 0.39 to 0.67), with a specificity of 0.88 (95% CI 0.83 to 0.92) on whole gland. The peripheral zone pooled sensitivity was 0.70 (95% CI 0.46 to 0.86), with a specificity of 0.88 (95% CI 0.76 to 0.94). Compared with T2-weighted imaging (T2WI), DCE was statistically superior to T2. In conclusion, DCE had relatively high specificity in detecting PCa but relatively low sensitivity as a complementary functional method. DCE-MRI might help clinicians exclude cases of normal tissue and serve as an adjunct to conventional imaging when seeking to identify tumor foci in patients with PCa.

SUBMITTER: Chen Z 

PROVIDER: S-EPMC5652829 | biostudies-other | 2017 Sep

REPOSITORIES: biostudies-other

altmetric image

Publications

Accuracy of dynamic contrast-enhanced magnetic resonance imaging in the diagnosis of prostate cancer: systematic review and meta-analysis.

Chen Zhiqiang Z   Zheng Yi Y   Ji Guanghai G   Liu Xinxin X   Li Peng P   Cai Lei L   Guo Yulin Y   Yang Jian J  

Oncotarget 20170817 44


The goals of this meta-analysis were to assess the effectiveness of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) in patients with prostate carcinoma (PCa) and to explore the risk profiles with the highest benefit. Systematic electronic searched were conducted in database. We used patient-based and biopsy-based pooled weighted estimates of the sensitivity, specificity, and a summary receiver operating characteristic (SROC) curve for assessing the diagnostic performance of DCE. W  ...[more]

Similar Datasets

| S-EPMC7215029 | biostudies-literature
| S-EPMC5522164 | biostudies-other
| S-EPMC7765071 | biostudies-literature
| S-EPMC6226386 | biostudies-literature
| S-EPMC5810424 | biostudies-literature
| S-EPMC2435006 | biostudies-literature
| S-EPMC6372178 | biostudies-literature
| S-EPMC6745862 | biostudies-literature
| S-EPMC5443513 | biostudies-literature
| S-EPMC4891499 | biostudies-literature