Unknown

Dataset Information

0

High-speed, high-frequency ultrasound, in utero vector-flow imaging of mouse embryos.


ABSTRACT: Real-time imaging of the embryonic murine cardiovascular system is challenging due to the small size of the mouse embryo and rapid heart rate. High-frequency, linear-array ultrasound systems designed for small-animal imaging provide high-frame-rate and Doppler modes but are limited in regards to the field of view that can be imaged at fine-temporal and -spatial resolution. Here, a plane-wave imaging method was used to obtain high-speed image data from in utero mouse embryos and multi-angle, vector-flow algorithms were applied to the data to provide information on blood flow patterns in major organs. An 18-MHz linear array was used to acquire plane-wave data at absolute frame rates ?10?kHz using a set of fixed transmission angles. After beamforming, vector-flow processing and image compounding, effective frame rates were on the order of 2?kHz. Data were acquired from the embryonic liver, heart and umbilical cord. Vector-flow results clearly revealed the complex nature of blood-flow patterns in the embryo with fine-temporal and -spatial resolution.

SUBMITTER: Ketterling JA 

PROVIDER: S-EPMC5709407 | biostudies-other | 2017 Nov

REPOSITORIES: biostudies-other

altmetric image

Publications

High-speed, high-frequency ultrasound, in utero vector-flow imaging of mouse embryos.

Ketterling Jeffrey A JA   Aristizábal Orlando O   Yiu Billy Y S BYS   Turnbull Daniel H DH   Phoon Colin K L CKL   Yu Alfred C H ACH   Silverman Ronald H RH  

Scientific reports 20171130 1


Real-time imaging of the embryonic murine cardiovascular system is challenging due to the small size of the mouse embryo and rapid heart rate. High-frequency, linear-array ultrasound systems designed for small-animal imaging provide high-frame-rate and Doppler modes but are limited in regards to the field of view that can be imaged at fine-temporal and -spatial resolution. Here, a plane-wave imaging method was used to obtain high-speed image data from in utero mouse embryos and multi-angle, vect  ...[more]

Similar Datasets

| S-EPMC6707714 | biostudies-literature
| S-EPMC9208600 | biostudies-literature
| S-EPMC7802269 | biostudies-literature
| S-EPMC5438320 | biostudies-literature
| S-EPMC6488013 | biostudies-literature
| S-EPMC6690022 | biostudies-literature
| S-EPMC6930322 | biostudies-literature
| S-EPMC7506572 | biostudies-literature
| S-EPMC7646360 | biostudies-literature
| S-EPMC5215385 | biostudies-literature