Unknown

Dataset Information

0

Automated histological classification of whole slide images of colorectal biopsy specimens.


ABSTRACT: An automated image analysis system, e-Pathologist, was developed to improve the quality of colorectal biopsy diagnostics in routine pathology practice.The aim of the study was to evaluate the classification accuracy of the e-Pathologist image analysis software in the setting of routine pathology practice in two institutions.In total, 1328 colorectal tissue specimens were consecutively obtained from two hospitals (1077 tissues from Tokyo hospital, and 251 tissues from East hospital) and the stained specimen slides were anonymized and digitized. At least two experienced gastrointestinal pathologists evaluated each slide for pathological diagnosis. We compared the 3-tier classification results (carcinoma or suspicion of carcinoma, adenoma, and lastly negative for a neoplastic lesion) between the human pathologists and that of e-Pathologist.For the Tokyo hospital specimens, all carcinoma tissues were correctly classified (n=112), and 9.9% (80/810) of the adenoma tissues were incorrectly classified as negative. For the East hospital specimens, 0 out of the 51 adenoma tissues were incorrectly classified as negative while 9.3% (11/118) of the carcinoma tissues were incorrectly classified as either adenoma, or negative. For the Tokyo and East hospital datasets, the undetected rate of carcinoma, undetected rate of adenoma, and over-detected proportion were 0% and 9.3%, 9.9% and 0%, and 36.1% and 27.1%, respectively.This image analysis system requires some improvements; however, it has the potential to assist pathologists in quality improvement of routine pathological practice in the not too distant future.

SUBMITTER: Yoshida H 

PROVIDER: S-EPMC5710880 | biostudies-other | 2017 Oct

REPOSITORIES: biostudies-other

altmetric image

Publications

Automated histological classification of whole slide images of colorectal biopsy specimens.

Yoshida Hiroshi H   Yamashita Yoshiko Y   Shimazu Taichi T   Cosatto Eric E   Kiyuna Tomoharu T   Taniguchi Hirokazu H   Sekine Shigeki S   Ochiai Atsushi A  

Oncotarget 20171012 53


<h4>Background</h4>An automated image analysis system, e-Pathologist, was developed to improve the quality of colorectal biopsy diagnostics in routine pathology practice.<h4>Objective</h4>The aim of the study was to evaluate the classification accuracy of the e-Pathologist image analysis software in the setting of routine pathology practice in two institutions.<h4>Materials and methods</h4>In total, 1328 colorectal tissue specimens were consecutively obtained from two hospitals (1077 tissues fro  ...[more]

Similar Datasets

| S-EPMC5545773 | biostudies-other
| S-EPMC3862630 | biostudies-literature
| S-EPMC4220929 | biostudies-literature
| S-EPMC6529804 | biostudies-literature
| S-EPMC8511039 | biostudies-literature
| S-EPMC4277457 | biostudies-literature
| S-EPMC4662482 | biostudies-literature
| S-EPMC9329279 | biostudies-literature
| S-EPMC5008750 | biostudies-literature
| S-EPMC5550903 | biostudies-other