An 8-channel Tx/Rx dipole array combined with 16 Rx loops for high-resolution functional cardiac imaging at 7 T.


ABSTRACT: To demonstrate imaging performance for cardiac MR imaging at 7 T using a coil array of 8 transmit/receive dipole antennas and 16 receive loops.An 8-channel dipole array was extended by adding 16 receive-only loops. Average power constraints were determined by electromagnetic simulations. Cine imaging was performed on eight healthy subjects. Geometrical factor (g-factor) maps were calculated to assess acceleration performance. Signal-to-noise ratio (SNR)-scaled images were reconstructed for different combinations of receive channels, to demonstrate the SNR benefits of combining loops and dipoles.The overall image quality of the cardiac functional images was rated a 2.6 on a 4-point scale by two experienced radiologists. Imaging results at different acceleration factors demonstrate that acceleration factors up to 6 could be obtained while keeping the average g-factor below 1.27. SNR maps demonstrate that combining loops and dipoles provides a more than 50% enhancement of the SNR in the heart, compared to a situation where only loops or dipoles are used.This work demonstrates the performance of a combined loop/dipole array for cardiac imaging at 7 T. With this array, acceleration factors of 6 are possible without increasing the average g-factor in the heart beyond 1.27. Combining loops and dipoles in receive mode enhances the SNR compared to receiving with loops or dipoles only.

SUBMITTER: Steensma BR 

PROVIDER: S-EPMC5813068 | biostudies-other | 2018 Feb

REPOSITORIES: biostudies-other

altmetric image

Publications

An 8-channel Tx/Rx dipole array combined with 16 Rx loops for high-resolution functional cardiac imaging at 7 T.

Steensma Bart R BR   Voogt Ingmar J IJ   Leiner Tim T   Luijten Peter R PR   Habets Jesse J   Klomp Dennis W J DWJ   van den Berg Cornelis A T CAT   Raaijmakers Alexander J E AJE  

Magma (New York, N.Y.) 20171124 1


<h4>Objective</h4>To demonstrate imaging performance for cardiac MR imaging at 7 T using a coil array of 8 transmit/receive dipole antennas and 16 receive loops.<h4>Materials and methods</h4>An 8-channel dipole array was extended by adding 16 receive-only loops. Average power constraints were determined by electromagnetic simulations. Cine imaging was performed on eight healthy subjects. Geometrical factor (g-factor) maps were calculated to assess acceleration performance. Signal-to-noise ratio  ...[more]

Similar Datasets

| S-EPMC4988950 | biostudies-other
| S-EPMC6618274 | biostudies-literature
| S-EPMC9675905 | biostudies-literature
| S-EPMC7309650 | biostudies-literature
| S-EPMC4771493 | biostudies-literature
| S-EPMC2799702 | biostudies-literature
| S-EPMC8078892 | biostudies-literature
| S-EPMC9463228 | biostudies-literature
| S-EPMC4801717 | biostudies-literature
| S-EPMC5910212 | biostudies-literature