Unknown

Dataset Information

0

Supra-threshold auditory brainstem response amplitudes in humans: Test-retest reliability, electrode montage and noise exposure.


ABSTRACT: The auditory brainstem response (ABR) is a sub-cortical evoked potential in which a series of well-defined waves occur in the first 10?ms after the onset of an auditory stimulus. Wave V of the ABR, particularly wave V latency, has been shown to be remarkably stable over time in individual listeners. However, little attention has been paid to the reliability of wave I, which reflects auditory nerve activity. This ABR component has attracted interest recently, as wave I amplitude has been identified as a possible non-invasive measure of noise-induced cochlear synaptopathy. The current study aimed to determine whether ABR wave I amplitude has sufficient test-retest reliability to detect impaired auditory nerve function in an otherwise normal-hearing listener. Thirty normal-hearing females were tested, divided equally into low- and high-noise exposure groups. The stimulus was an 80?dB nHL click. ABR recordings were made from the ipsilateral mastoid and from the ear canal (using a tiptrode). Although there was some variability between listeners, wave I amplitude had high test-retest reliability, with an intraclass correlation coefficient (ICC) comparable to that for wave V amplitude. There were slight gains in reliability for wave I amplitude when recording from the ear canal (ICC of 0.88) compared to the mastoid (ICC of 0.85). The summating potential (SP) and ratio of SP to wave I were also quantified and found to be much less reliable than measures of wave I and V amplitude. Finally, we found no significant differences in the amplitude of any wave components between low- and high-noise exposure groups. We conclude that, if the other sources of between-subject variability can be controlled, wave I amplitude is sufficiently reliable to accurately characterize individual differences in auditory nerve function.

SUBMITTER: Prendergast G 

PROVIDER: S-EPMC5993871 | biostudies-other | 2018 Jul

REPOSITORIES: biostudies-other

altmetric image

Publications

Supra-threshold auditory brainstem response amplitudes in humans: Test-retest reliability, electrode montage and noise exposure.

Prendergast Garreth G   Tu Wenhe W   Guest Hannah H   Millman Rebecca E RE   Kluk Karolina K   Couth Samuel S   Munro Kevin J KJ   Plack Christopher J CJ  

Hearing research 20180406


The auditory brainstem response (ABR) is a sub-cortical evoked potential in which a series of well-defined waves occur in the first 10 ms after the onset of an auditory stimulus. Wave V of the ABR, particularly wave V latency, has been shown to be remarkably stable over time in individual listeners. However, little attention has been paid to the reliability of wave I, which reflects auditory nerve activity. This ABR component has attracted interest recently, as wave I amplitude has been identifi  ...[more]

Similar Datasets

| S-EPMC9354017 | biostudies-literature
| S-EPMC3439509 | biostudies-literature
| S-EPMC8571499 | biostudies-literature
| S-EPMC3899078 | biostudies-literature
| S-EPMC7178521 | biostudies-literature
| S-EPMC6786607 | biostudies-literature
| S-EPMC7084471 | biostudies-literature
| S-EPMC7802960 | biostudies-literature
| S-EPMC7198904 | biostudies-literature
| S-EPMC4516322 | biostudies-other