Unknown

Dataset Information

0

Using the isotope effect to probe an aggregation induced emission mechanism: theoretical prediction and experimental validation.


ABSTRACT: Aggregation-induced emission (AIE) has become a hot topic for a variety of potential applications, but the understanding of its working mechanism is still under scrutiny. Herein, we proposed the use of the isotope effect (IE) to identify the AIE mechanism: under the restriction of an internal motion mechanism, the IE is pronouncedly different in excited-state decay rates when contrasting AIE luminogens (AIEgens) and non-AIEgens in theoretical calculations. For the complete deuteration of AIEgens, the IE of nonradiative decay rate in solution (<-10%) is much weaker than that (-65% to -95%) in aggregate, because the former stems from the overall results of competitive vibronic coupling and the severe mixing of low-frequency modes while the latter mainly comes from the vibronic coupling only. The experimental results confirm the isotopic "jump" behaviors in AIEgens well. However, non-AIEgens exhibit equivalent IEs (-40% to -90%) in both solution and solid phases. Further partial deuteration schemes for the 6-ring AIE analogues show positional dependence.

SUBMITTER: Zhang T 

PROVIDER: S-EPMC6022082 | biostudies-other | 2016 Aug

REPOSITORIES: biostudies-other

altmetric image

Publications

Using the isotope effect to probe an aggregation induced emission mechanism: theoretical prediction and experimental validation.

Zhang Tian T   Peng Qian Q   Quan Changyun C   Nie Han H   Niu Yingli Y   Xie Yujun Y   Zhao Zujin Z   Tang Ben Zhong BZ   Shuai Zhigang Z  

Chemical science 20160511 8


Aggregation-induced emission (AIE) has become a hot topic for a variety of potential applications, but the understanding of its working mechanism is still under scrutiny. Herein, we proposed the use of the isotope effect (IE) to identify the AIE mechanism: under the restriction of an internal motion mechanism, the IE is pronouncedly different in excited-state decay rates when contrasting AIE luminogens (AIEgens) and non-AIEgens in theoretical calculations. For the complete deuteration of AIEgens  ...[more]

Similar Datasets

| S-EPMC10856369 | biostudies-literature
| S-EPMC9080023 | biostudies-literature
| S-EPMC9089335 | biostudies-literature
| S-EPMC4167053 | biostudies-literature
| S-EPMC6644794 | biostudies-literature
| S-EPMC10057136 | biostudies-literature
| S-EPMC10054884 | biostudies-literature
| S-EPMC6227967 | biostudies-literature
| S-EPMC5304165 | biostudies-literature
| S-EPMC4812260 | biostudies-other