Unknown

Dataset Information

0

Reliability of In Vitro Methods Used to Measure Intrinsic Clearance of Hydrophobic Organic Chemicals by Rainbow Trout: Results of an International Ring Trial.


ABSTRACT: In vitro assays are widely employed to obtain intrinsic clearance estimates used in toxicokinetic modeling efforts. However, the reliability of these methods is seldom reported. Here we describe the results of an international ring trial designed to evaluate two in vitro assays used to measure intrinsic clearance in rainbow trout. An important application of these assays is to predict the effect of biotransformation on chemical bioaccumulation. Six laboratories performed substrate depletion experiments with cyclohexyl salicylate, fenthion, 4-n-nonylphenol, deltamethrin, methoxychlor, and pyrene using cryopreserved hepatocytes and liver S9 fractions from trout. Variability within and among laboratories was characterized as the percent coefficient of variation (CV) in measured in vitro intrinsic clearance rates (CLIN VITRO, INT; ml/h/mg protein or 106 cells) for each chemical and test system. Mean intralaboratory CVs for each test chemical averaged 18.9% for hepatocytes and 14.1% for S9 fractions, whereas interlaboratory CVs (all chemicals and all tests) averaged 30.1% for hepatocytes and 22.4% for S9 fractions. When CLIN VITRO, INT values were extrapolated to in vivo intrinsic clearance estimates (CLIN VIVO, INT; l/d/kg fish), both assays yielded similar levels of activity (<4-fold difference for all chemicals). Hepatic clearance rates (CLH; l/d/kg fish) calculated using data from both assays exhibited even better agreement. These findings show that both assays are highly reliable and suggest that either may be used to inform chemical bioaccumulation assessments for fish. This study highlights several issues related to the demonstration of assay reliability and may provide a template for evaluating other in vitro biotransformation assays.

SUBMITTER: Nichols J 

PROVIDER: S-EPMC6061802 | biostudies-other | 2018 Aug

REPOSITORIES: biostudies-other

altmetric image

Publications

Reliability of In Vitro Methods Used to Measure Intrinsic Clearance of Hydrophobic Organic Chemicals by Rainbow Trout: Results of an International Ring Trial.

Nichols John J   Fay Kellie K   Bernhard Mary Jo MJ   Bischof Ina I   Davis John J   Halder Marlies M   Hu Jing J   Johanning Karla K   Laue Heike H   Nabb Diane D   Schlechtriem Christian C   Segner Helmut H   Swintek Joe J   Weeks John J   Embry Michelle M  

Toxicological sciences : an official journal of the Society of Toxicology 20180801 2


In vitro assays are widely employed to obtain intrinsic clearance estimates used in toxicokinetic modeling efforts. However, the reliability of these methods is seldom reported. Here we describe the results of an international ring trial designed to evaluate two in vitro assays used to measure intrinsic clearance in rainbow trout. An important application of these assays is to predict the effect of biotransformation on chemical bioaccumulation. Six laboratories performed substrate depletion expe  ...[more]

Similar Datasets

| S-EPMC7962060 | biostudies-literature
| S-EPMC9589910 | biostudies-literature
| PRJNA868155 | ENA
| PRJNA629987 | ENA
| PRJNA732666 | ENA
| S-EPMC8557474 | biostudies-literature
2006-12-05 | GSE6416 | GEO
| PRJNA937442 | ENA
2010-06-05 | E-GEOD-6416 | biostudies-arrayexpress
| S-BSST1275 | biostudies-other