Unknown

Dataset Information

0

Comparative Analysis of Microcystin Prevalence in Michigan Lakes by Online Concentration LC/MS/MS and ELISA.


ABSTRACT: Fast and reliable workflows are needed to quantitate microcystins (MCs), a ubiquitous class of hepatotoxic cyanotoxins, so that the impact of human and environmental exposure is assessed quickly and minimized. Our goal was to develop a high-throughput online concentration liquid chromatography tandem mass spectrometry (LC/MS/MS) workflow to quantitate the 12 commercially available MCs and nodularin in surface and drinking waters. The method run time was 8.5 min with detection limits in the low ng/L range and minimum reporting levels between 5 and 10 ng/L. This workflow was benchmarked by determining the prevalence of MCs and comparing the Adda-ELISA quantitation to our new workflow from 122 samples representing 31 waterbodies throughout Michigan. The frequency of MC occurrence was MC-LA > LR > RR > D-Asp³-LR > YR > HilR > WR > D-Asp³-RR > HtyR > LY = LW = LF, while MC-RR had the highest concentrations. MCs were detected in 33 samples and 13 of these samples had more than 20% of their total MC concentration from MCs not present in US Environmental Protection Agency (US EPA) Method 544. Furthermore, seasonal deviations between the LC/MS/MS and Adda-ELISA data suggest Adda-ELISA cross-reacts with MC degradation products. This workflow provides less than 24-h turnaround for quantification and also identified key differences between LC/MS/MS and ELISA quantitation that should be investigated further.

SUBMITTER: Birbeck JA 

PROVIDER: S-EPMC6356304 | biostudies-other | 2019 Jan

REPOSITORIES: biostudies-other

altmetric image

Publications

Comparative Analysis of Microcystin Prevalence in Michigan Lakes by Online Concentration LC/MS/MS and ELISA.

Birbeck Johnna A JA   Westrick Judy A JA   O'Neill Grace M GM   Spies Brian B   Szlag David C DC  

Toxins 20190101 1


Fast and reliable workflows are needed to quantitate microcystins (MCs), a ubiquitous class of hepatotoxic cyanotoxins, so that the impact of human and environmental exposure is assessed quickly and minimized. Our goal was to develop a high-throughput online concentration liquid chromatography tandem mass spectrometry (LC/MS/MS) workflow to quantitate the 12 commercially available MCs and nodularin in surface and drinking waters. The method run time was 8.5 min with detection limits in the low n  ...[more]

Similar Datasets

| S-EPMC6891738 | biostudies-literature
| S-EPMC5951789 | biostudies-literature
| S-EPMC7082718 | biostudies-literature
| S-EPMC5472028 | biostudies-literature
| S-EPMC4018675 | biostudies-literature
| S-EPMC8401233 | biostudies-literature
| S-EPMC4422731 | biostudies-literature
| S-EPMC9978588 | biostudies-literature
| S-EPMC3747030 | biostudies-literature
| S-EPMC6017919 | biostudies-literature